Geometry-Controlled Nickel Foil and Wire Electrodes for Non-Enzymatic Electrochemical Detection of Uric Acid

Rapid and reliable detection of uric acid (UA) is essential for the diagnosis and monitoring of metabolic disorders, including gout and renal dysfunction. In this work, geometry-controlled nickel foil (NFE) and nickel wire (NWE) electrodes were developed as simple and cost-effective platforms for non-enzymatic electrochemical detection of UA. The electrodes were characterized by X-ray diffraction, FESEM, EDS, Raman spectroscopy, and XPS, confirming high crystallinity, high purity, and the formation of electrochemically active Ni(OH)2/NiOOH surface species after electrochemical activation. CV exhibited a well-defined Ni(II)/Ni(III) redox couple consistent with the proposed Ni(OH)2 oxidation of UA. EIS and Tafel analysis showed lower charge-transfer resistance and a lower apparent Tafel slope for the NWE than for the NFE, suggesting comparatively favourable interfacial charge-transfer characteristics under the employed conditions. DPV exhibited a linear response over the concentration range of 16.67–166.67 μM, with detection limits of 4.86 μM and 2.02 μM for the NFE and NWE, respectively. Calibration-validation and recovery studies in artificial sweat demonstrated satisfactory analytical accuracy and precision, providing preliminary basis for the potential applicability of the developed electrodes in physiologically relevant matrices.

Authors

Institutions

Publication Details

Journal
Industrial & Engineering Chemistry Research
Published
2026-11-25
DOI
https://doi.org/10.1021/acs.iecr.6c01596
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Geometry-Controlled Nickel Foil and Wire Electrodes for Non-Enzymatic Electrochemical Detection of Uric Acid

Adhidesh S. Kumawat, Prakash Kumar
Industrial & Engineering Chemistry Research
Electrochemical sensors and biosensors
article

Geometry-Controlled Nickel Foil and Wire Electrodes for Non-Enzymatic Electrochemical Detection of Uric Acid

Adhidesh S. Kumawat, Prakash Kumar
article en

Abstract

Rapid and reliable detection of uric acid (UA) is essential for the diagnosis and monitoring of metabolic disorders, including gout and renal dysfunction. In this work, geometry-controlled nickel foil (NFE) and nickel wire (NWE) electrodes were developed as simple and cost-effective platforms for non-enzymatic electrochemical detection of UA. The electrodes were characterized by X-ray diffraction, FESEM, EDS, Raman spectroscopy, and XPS, confirming high crystallinity, high purity, and the formation of electrochemically active Ni(OH)2/NiOOH surface species after electrochemical activation. CV exhibited a well-defined Ni(II)/Ni(III) redox couple consistent with the proposed Ni(OH)2 oxidation of UA. EIS and Tafel analysis showed lower charge-transfer resistance and a lower apparent Tafel slope for the NWE than for the NFE, suggesting comparatively favourable interfacial charge-transfer characteristics under the employed conditions. DPV exhibited a linear response over the concentration range of 16.67–166.67 μM, with detection limits of 4.86 μM and 2.02 μM for the NFE and NWE, respectively. Calibration-validation and recovery studies in artificial sweat demonstrated satisfactory analytical accuracy and precision, providing preliminary basis for the potential applicability of the developed electrodes in physiologically relevant matrices.

Industrial & Engineering Chemistry Research
National Institute of Technology Rourkela (IN), Swami Keshwanand Rajasthan Agricultural University (IN)
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon