Clinical outcomes of posterior-stabilized versus cruciate-retaining ANTHEM total knee arthroplasty using imageless robotic-assisted personalized alignment: a retrospective comparative cohort study

Posterior-stabilized (PS) and cruciate-retaining (CR) total knee arthroplasty (TKA) show no consistent clinical superiority. This study compared 2-year patient-reported outcomes, responder rates, complications, and revisions between PS and CR ANTHEM TKA using imageless robotic-assisted personalized alignment. This retrospective cohort included 858 primary ANTHEM TKAs (167 CR and 691 PS). All procedures used CORI robotic-assisted personalized alignment. Outcomes included the Knee injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS-JR), visual analog scale (VAS) pain, satisfaction, and general health scores. Entropy-balanced inverse probability weighting adjusted for baseline differences. Responder rates and time to patient acceptable symptom state (PASS) were evaluated. After weighting, measured covariates were balanced and KOOS-JR improved substantially in both groups and did not differ at any postoperative time point. At 1 year, adjusted KOOS-JR scores were 84.1 for CR and 84.7 for PS (difference, - 0.61; 95% CI, - 2.80 to 1.58; p = .58); at 2 years, scores were 86.4 and 86.7, respectively (difference, - 0.38; 95% CI, - 2.31 to 1.55; p = .70). VAS pain, general health, satisfaction, and responder rates were also similar after multiplicity correction. CR patients achieved PASS earlier, but both groups exceeded 99% by 2 years. Complications occurred in 2 CR cases (1.2%) and 7 PS cases (1.0%); revisions occurred in 0 and 6 cases (0.9%), respectively. Using imageless robotic-assisted personalized alignment, CR and PS ANTHEM TKA produced substantial and comparable improvements in pain and patient-reported outcomes. CR was associated with earlier PASS achievement, but final outcomes and short-term complication and revision rates did not differ significantly.

Authors

Institutions

Publication Details

Journal
Journal of Robotic Surgery
Published
2026-11-25
DOI
https://doi.org/10.1007/s11701-026-04219-2
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Clinical outcomes of posterior-stabilized versus cruciate-retaining ANTHEM total knee arthroplasty using imageless robotic-assisted personalized alignment: a retrospective comparative cohort study

Ali Albelooshi, Saeed Althani, Zainab Aqeel Khan, Elhadi Babikir et al.
Journal of Robotic Surgery
Total Knee Arthroplasty Outcomes
article

Clinical outcomes of posterior-stabilized versus cruciate-retaining ANTHEM total knee arthroplasty using imageless robotic-assisted personalized alignment: a retrospective comparative cohort study

Ali Albelooshi, Saeed Althani, Zainab Aqeel Khan, Elhadi Babikir, Abdallah Reda Bedair Elgouhary
article en

Abstract

Posterior-stabilized (PS) and cruciate-retaining (CR) total knee arthroplasty (TKA) show no consistent clinical superiority. This study compared 2-year patient-reported outcomes, responder rates, complications, and revisions between PS and CR ANTHEM TKA using imageless robotic-assisted personalized alignment. This retrospective cohort included 858 primary ANTHEM TKAs (167 CR and 691 PS). All procedures used CORI robotic-assisted personalized alignment. Outcomes included the Knee injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS-JR), visual analog scale (VAS) pain, satisfaction, and general health scores. Entropy-balanced inverse probability weighting adjusted for baseline differences. Responder rates and time to patient acceptable symptom state (PASS) were evaluated. After weighting, measured covariates were balanced and KOOS-JR improved substantially in both groups and did not differ at any postoperative time point. At 1 year, adjusted KOOS-JR scores were 84.1 for CR and 84.7 for PS (difference, - 0.61; 95% CI, - 2.80 to 1.58; p = .58); at 2 years, scores were 86.4 and 86.7, respectively (difference, - 0.38; 95% CI, - 2.31 to 1.55; p = .70). VAS pain, general health, satisfaction, and responder rates were also similar after multiplicity correction. CR patients achieved PASS earlier, but both groups exceeded 99% by 2 years. Complications occurred in 2 CR cases (1.2%) and 7 PS cases (1.0%); revisions occurred in 0 and 6 cases (0.9%), respectively. Using imageless robotic-assisted personalized alignment, CR and PS ANTHEM TKA produced substantial and comparable improvements in pain and patient-reported outcomes. CR was associated with earlier PASS achievement, but final outcomes and short-term complication and revision rates did not differ significantly.

Journal of Robotic SurgeryVol. 20(1)
Rashid Hospital (AE), Karolinska Institutet (SE), Mediclinic City Hospital (AE)
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon