Gearbox Fault Localisation Using Vibration and Acoustic Features with Implications for Maintenance Decisions

Localising a gearbox fault to the responsible member of a gear pair can focus subsequent inspection, but pooled classification scores do not show how performance changes with operating speed or which component is selected when a prediction is wrong. This study compares vibration, airborne acoustic and hybrid descriptors for distinguishing a defective 25-tooth driving pinion (Condition B) from a defective 75-tooth driven gear (Condition C). A total of 50 records, each lasting five seconds, were collected at a sampling frequency of 6400 Hz across five operating speeds ranging from 400 to 2000 rpm. Five repetitions were obtained for each condition at every speed. Trial-level root-mean-square and Z-Freq features were classified using radial basis function support vector machines, K-nearest neighbours and bagged trees. Leave-one-speed-out validation used training-fold standardisation and deterministic seeds for stochastic models. Vibration KNN produced the highest pooled accuracy and macro-F1, 76.0% and 0.760. Its fold accuracy averaged 76.0 ± 25.1% and ranged from 50 to 100%. Hybrid KNN reached 68.0% and 0.678, while acoustic KNN reached 56.0% and 0.559. Vibration KNN made seven B-to-C and five C-to-B errors; vibration SVM made one and twelve. Fusion improved on acoustic inputs for all three classifiers, but exceeded vibration only for bagged trees. These results show that the preferred sensing and model combination depends on performance across operating speeds and on the direction of diagnostic error. The study provides a reproducible component-localisation comparison for this gearbox and a basis for broader validation with healthy states, additional loads, defect severities and independent gearboxes. The workflow provides a transparent basis for future validation under broader gearbox operating conditions.

Authors

Institutions

Publication Details

Journal
International Journal of Research and Innovation in Social Science
Published
2026-11-25
DOI
https://doi.org/10.47772/ijriss.2026.101100268
Primary Topic
Machine Fault Diagnosis Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Gearbox Fault Localisation Using Vibration and Acoustic Features with Implications for Maintenance Decisions

Muhammad Noorazlan Shah Zainudin, Nor Azazi Ngatiman, Afdiman Anuar, Sharif bin Mohd Zaki et al.
International Journal of Research and Innovation in Social Science
Machine Fault Diagnosis Techniques
article

Gearbox Fault Localisation Using Vibration and Acoustic Features with Implications for Maintenance Decisions

Muhammad Noorazlan Shah Zainudin, Nor Azazi Ngatiman, Afdiman Anuar, Sharif bin Mohd Zaki, Shahrul Nazrin Khalid
article en

Abstract

Localising a gearbox fault to the responsible member of a gear pair can focus subsequent inspection, but pooled classification scores do not show how performance changes with operating speed or which component is selected when a prediction is wrong. This study compares vibration, airborne acoustic and hybrid descriptors for distinguishing a defective 25-tooth driving pinion (Condition B) from a defective 75-tooth driven gear (Condition C). A total of 50 records, each lasting five seconds, were collected at a sampling frequency of 6400 Hz across five operating speeds ranging from 400 to 2000 rpm. Five repetitions were obtained for each condition at every speed. Trial-level root-mean-square and Z-Freq features were classified using radial basis function support vector machines, K-nearest neighbours and bagged trees. Leave-one-speed-out validation used training-fold standardisation and deterministic seeds for stochastic models. Vibration KNN produced the highest pooled accuracy and macro-F1, 76.0% and 0.760. Its fold accuracy averaged 76.0 ± 25.1% and ranged from 50 to 100%. Hybrid KNN reached 68.0% and 0.678, while acoustic KNN reached 56.0% and 0.559. Vibration KNN made seven B-to-C and five C-to-B errors; vibration SVM made one and twelve. Fusion improved on acoustic inputs for all three classifiers, but exceeded vibration only for bagged trees. These results show that the preferred sensing and model combination depends on performance across operating speeds and on the direction of diagnostic error. The study provides a reproducible component-localisation comparison for this gearbox and a basis for broader validation with healthy states, additional loads, defect severities and independent gearboxes. The workflow provides a transparent basis for future validation under broader gearbox operating conditions.

International Journal of Research and Innovation in Social ScienceVol. 10(11)
Technical University of Malaysia Malacca (MY)
Machine Fault Diagnosis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon