Geometry- and dynamics-based generation and imputation of neonatal pose sequences: linear, angular, inertia-based, and LSTM models
Introduction Limited neonatal motion data make it difficult to develop and evaluate methods for generating infant pose sequences. A key challenge is maintaining movement dynamics and body geometry when extending short observed pose sequences. Methods In this proof-of-concept computational study, we compared four algorithms for deterministic pose continuation: PoseLineoTrack, PoseAnguTrack, PoseInertiTrack, and PoseLSTMNet. Imputation was examined as an additional application. Pose datasets from five independent male infants were obtained from the NeoVault repository. Two image-relative datasets and a separate three-infant hip-centered replication were evaluated under distinct protocols. The clinical protocol used training-only normalization and separate validation partitions, while public MINI-RGBD models were fitted separately. Following a finite observed seed, all subsequent coordinates were generated autonomously over 1–60 frames. Additional analyses examined uncertainty, parameter sensitivity, temporal coordination, dynamical baselines, static controls, masked reconstruction, and reference-matched continuations extending to 2,500 frames. Results Among the four algorithms, PoseInertiTrack achieved the lowest 30-frame cumulative normalized RMSE on Subject 2 (0.2724) and across six public test sequences (0.4307). However, its Subject 2 distal speed and variance ratios were 0.353 and 0.568, respectively, indicating attenuated movement. In the separate hip-centered replication, PoseLSTMNet achieved the lowest RMSE on both test infants (0.2632 and 0.3351), but the corresponding speed ratios (0.098 and 0.063) indicated substantial movement attenuation. Additional analyses distinguished coordinate agreement from realistic movement synthesis and characterized the limitations of numerical accuracy. Discussion This study provides a reproducible comparison of neonatal pose-generation algorithms while identifying important movement-fidelity limitations. The small all-male cohort, tracker-derived references, development-stage inspection, and absence of clinical or augmentation validation constrain generalizability. Broader validation across diverse neonatal populations remains necessary.
Authors
- Simón Pedro Lubián‐López (ORCID: https://orcid.org/0000-0002-2937-778X)
- Janet Pigueiras-del-Real (ORCID: https://orcid.org/0009-0005-0124-4140)
- Ángel Ruíz-Zafra (ORCID: https://orcid.org/0000-0003-2626-2212)
- Isabel Benavente‐Fernández (ORCID: https://orcid.org/0000-0001-9276-1912)
- Marco A. Deriu (ORCID: https://orcid.org/0000-0003-1918-1772)
- Syed Adil Hussain Shah (ORCID: https://orcid.org/0009-0008-3916-1692)
- Angelo Di Terlizzi
- Konstantinos Panagiotopoulos (ORCID: https://orcid.org/0000-0001-5034-378X)
- Syed Baqir Hussain Shah
- Lionel C. Gontard
- Syed Taimoor Hussain Shah
Institutions
- COMSATS University Islamabad (PK)
- Universidad de Granada (ES)
- Politecnico di Torino (IT)
- Fudan University (CN)
- Universidad de Cádiz (ES)
- Biomedical Research and Innovation Institute of Cadiz (ES)
- Hospital Universitario Puerta del Mar (ES)
Publication Details
- Journal
- Frontiers in Big Data
- Published
- 2026-11-25
- DOI
- https://doi.org/10.3389/fdata.2026.1872138
- Primary Topic
- Human Motion and Animation
- Type
- article
- Field-Weighted Citation Impact
- 0.00