Contactless Frailty Screening Using Heart Rate Variability and Eyelid Motion from a Mobile Device Camera in Hospitalized Older Adults: Observational Pilot Study (Preprint)

BACKGROUND Frailty predicts adverse outcomes in older adults. However comprehensive geriatric assessment (CGA) requires trained staff and time, which limits routine screening. Remote photoplethysmography can estimate heart rate variability (HRV) from a facial video recorded with a standard camera, and the same video captures eyelid motion, without requiring sensors attached to the patient. Whether these camera-derived metrics reflect frailty is unknown. OBJECTIVE We evaluated the feasibility of bedside facial video recording with a mobile device in hospitalized older adults and examined whether the derived HRV and eyelid motion metrics are associated with frailty, distinguish participants with and without frailty, and are reliable across repeated recordings. METHODS In this observational pilot study at a tertiary hospital in the Republic of Korea, we enrolled inpatients aged 65 years or older from August 11 to December 22, 2025. Frailty was defined as a CGA-based Multidimensional Frailty Score (MFS) greater than 5. Bedside sessions were repeated on consecutive days when feasible. At each session, a tripod-mounted tablet recorded three 1-minute facial videos, yielding 9 HRV and 3 eyelid motion metrics per participant-day. We assessed associations with the MFS using linear mixed-effects models adjusted for age and sex, frailty discrimination using logistic regression with participant-level cross-validation, and test-retest reliability using intraclass correlation coefficients (ICCs). RESULTS Of 120 participants (median age 75.0 years, IQR 68.8-81.0), 38 (31.7%) were women and 73 (60.8%) were frail. Of 316 scheduled sessions, 287 (90.8%) were performed and 282 (89.2%) yielded archived recordings. After exclusion of participants with atrial fibrillation (n=12) or inadequate signal quality (n=30), 78 participants (136 participant-days) were analyzed. Greater frailty was associated with lower low-frequency HRV power (standardized β −0.34, 95% CI −0.52 to −0.16) and longer eyelid closing time (β 0.30, 95% CI 0.11 to 0.48), the only 2 of 12 metrics that remained significant after correction for multiple comparisons. The area under the receiver operating characteristic curve (AUC) for frailty was 0.73 (95% CI 0.58-0.85) with demographic features alone and 0.85 (95% CI 0.76-0.92) when HRV features were added (P=.02). The AUC was similar (0.84) when eyelid motion features were also added. Single-recording within-day ICCs were moderate for most HRV metrics (0.52-0.73, rising to 0.69-0.85 for the mean of 2 recordings) and poor for the eyelid motion metrics (0.00-0.45). CONCLUSIONS Contactless facial video recording with a mobile device was feasible at the bedside in hospitalized older adults, and lower low-frequency HRV power and longer eyelid closing time were associated with frailty. HRV features improved frailty discrimination beyond demographic features, with similar discrimination after eyelid motion features were added. This approach may serve as an adjunct for frailty screening after validation against an electrocardiographic reference, in larger and more diverse populations, and against clinical outcomes.

Authors

Publication Details

Published
2026-11-25
DOI
https://doi.org/10.2196/preprints.117783
Primary Topic
Frailty in Older Adults
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Contactless Frailty Screening Using Heart Rate Variability and Eyelid Motion from a Mobile Device Camera in Hospitalized Older Adults: Observational Pilot Study (Preprint)

Jung Hun Ohn, Shin Young Ahn, Hee-Sun Park, Nak‐Hyun Kim et al.
Frailty in Older Adults
preprint

Contactless Frailty Screening Using Heart Rate Variability and Eyelid Motion from a Mobile Device Camera in Hospitalized Older Adults: Observational Pilot Study (Preprint)

Jung Hun Ohn, Shin Young Ahn, Hee-Sun Park, Nak‐Hyun Kim, Jongin Kim, Yejee Lim, Jihye Kim, Hye Won Kim, Jongchan Lee, Eun Sun Kim, Jiwon Ryu, Sun‐wook Kim
preprint en

Abstract

BACKGROUND Frailty predicts adverse outcomes in older adults. However comprehensive geriatric assessment (CGA) requires trained staff and time, which limits routine screening. Remote photoplethysmography can estimate heart rate variability (HRV) from a facial video recorded with a standard camera, and the same video captures eyelid motion, without requiring sensors attached to the patient. Whether these camera-derived metrics reflect frailty is unknown. OBJECTIVE We evaluated the feasibility of bedside facial video recording with a mobile device in hospitalized older adults and examined whether the derived HRV and eyelid motion metrics are associated with frailty, distinguish participants with and without frailty, and are reliable across repeated recordings. METHODS In this observational pilot study at a tertiary hospital in the Republic of Korea, we enrolled inpatients aged 65 years or older from August 11 to December 22, 2025. Frailty was defined as a CGA-based Multidimensional Frailty Score (MFS) greater than 5. Bedside sessions were repeated on consecutive days when feasible. At each session, a tripod-mounted tablet recorded three 1-minute facial videos, yielding 9 HRV and 3 eyelid motion metrics per participant-day. We assessed associations with the MFS using linear mixed-effects models adjusted for age and sex, frailty discrimination using logistic regression with participant-level cross-validation, and test-retest reliability using intraclass correlation coefficients (ICCs). RESULTS Of 120 participants (median age 75.0 years, IQR 68.8-81.0), 38 (31.7%) were women and 73 (60.8%) were frail. Of 316 scheduled sessions, 287 (90.8%) were performed and 282 (89.2%) yielded archived recordings. After exclusion of participants with atrial fibrillation (n=12) or inadequate signal quality (n=30), 78 participants (136 participant-days) were analyzed. Greater frailty was associated with lower low-frequency HRV power (standardized β −0.34, 95% CI −0.52 to −0.16) and longer eyelid closing time (β 0.30, 95% CI 0.11 to 0.48), the only 2 of 12 metrics that remained significant after correction for multiple comparisons. The area under the receiver operating characteristic curve (AUC) for frailty was 0.73 (95% CI 0.58-0.85) with demographic features alone and 0.85 (95% CI 0.76-0.92) when HRV features were added (P=.02). The AUC was similar (0.84) when eyelid motion features were also added. Single-recording within-day ICCs were moderate for most HRV metrics (0.52-0.73, rising to 0.69-0.85 for the mean of 2 recordings) and poor for the eyelid motion metrics (0.00-0.45). CONCLUSIONS Contactless facial video recording with a mobile device was feasible at the bedside in hospitalized older adults, and lower low-frequency HRV power and longer eyelid closing time were associated with frailty. HRV features improved frailty discrimination beyond demographic features, with similar discrimination after eyelid motion features were added. This approach may serve as an adjunct for frailty screening after validation against an electrocardiographic reference, in larger and more diverse populations, and against clinical outcomes.

Frailty in Older Adults
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon