Effect of Potenciostatic Electrocoagulation Process Parameters on the Treatment of Effluents From Car Washing Stations: A Complete Kinetic Study

Vehicle wash station effluents (VWSE) are potential contaminants of water resources. These effluents contain metallic compounds such as chromium, lead, zinc, and cadmium, as well as organic contaminants such as surfactants, oils, and greases. As a consequence, these effluents have high chemical oxygen demand (COD) values. In this study, the electrocoagulation (EC) process with aluminum electrodes was used to treat VWSE, with the aim of reducing turbidity, COD, and surfactant concentrations. The studies evaluated the effect of pH, treatment time, electric potential difference, and electric current density on the reduction of these physical-chemical parameters. The experiments were designed using the 22-type full factorial experimental design methodology, with triplicate at the central point. VWSE samples were collected at a single location and on different days. The VWSE without EC treatment presented values of 609 mgo 2 L − 1 for COD, 66.3 mg L − 1 for surfactant concentration (MBAS) and 653 ± 208 NTU for turbidity. The electrical conductivity of all samples was adjusted to 900 ± 100 µS cm − 1 with the addition of a sodium chloride solution (NaCl – 1 M). The results showed that the potentiostatic mode for the EC process presents the greatest efficiency in reducing the physical-chemical parameters of VWSE. It was found that the pH values and treatment time influence the process of reducing the COD, MBAS and turbidity parameters. With the experimental condition of pH 5.5, with a treatment time of 315 min and an electrical potential difference of 10 V, it was possible to reduce the COD value by 89.0% and the MBAS value by 99.0%.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-25
DOI
https://doi.org/10.21203/rs.3.rs-11494451/v1
Primary Topic
Coagulation and Flocculation Studies
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Effect of Potenciostatic Electrocoagulation Process Parameters on the Treatment of Effluents From Car Washing Stations: A Complete Kinetic Study

Josiane Maria Muneron de Mello, Gustavo Lopes Colpani, Marcelo Guerreiro Crizel, Luciano Luiz Silva et al.
Research Square
Coagulation and Flocculation Studies
preprint

Effect of Potenciostatic Electrocoagulation Process Parameters on the Treatment of Effluents From Car Washing Stations: A Complete Kinetic Study

Josiane Maria Muneron de Mello, Gustavo Lopes Colpani, Marcelo Guerreiro Crizel, Luciano Luiz Silva, Márcio Antônio Fiori, Tiago Marquadt Barreto, Artur Sponchiado
preprint en

Abstract

Vehicle wash station effluents (VWSE) are potential contaminants of water resources. These effluents contain metallic compounds such as chromium, lead, zinc, and cadmium, as well as organic contaminants such as surfactants, oils, and greases. As a consequence, these effluents have high chemical oxygen demand (COD) values. In this study, the electrocoagulation (EC) process with aluminum electrodes was used to treat VWSE, with the aim of reducing turbidity, COD, and surfactant concentrations. The studies evaluated the effect of pH, treatment time, electric potential difference, and electric current density on the reduction of these physical-chemical parameters. The experiments were designed using the 22-type full factorial experimental design methodology, with triplicate at the central point. VWSE samples were collected at a single location and on different days. The VWSE without EC treatment presented values of 609 mgo 2 L − 1 for COD, 66.3 mg L − 1 for surfactant concentration (MBAS) and 653 ± 208 NTU for turbidity. The electrical conductivity of all samples was adjusted to 900 ± 100 µS cm − 1 with the addition of a sodium chloride solution (NaCl – 1 M). The results showed that the potentiostatic mode for the EC process presents the greatest efficiency in reducing the physical-chemical parameters of VWSE. It was found that the pH values and treatment time influence the process of reducing the COD, MBAS and turbidity parameters. With the experimental condition of pH 5.5, with a treatment time of 315 min and an electrical potential difference of 10 V, it was possible to reduce the COD value by 89.0% and the MBAS value by 99.0%.

Research Square
Community University of Chapecó Region - Unochapecó (BR)
Coagulation and Flocculation Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon