Life-Cycle Environmental Assessment of a 90kW Solar Photovoltaic Adiabatic Compressed Air Energy Storage System (SPV-A-CAES) for Agricultural Electrification

This paper presents a screening life-cycle environmental assessment of a 90 kW solar photovoltaic adiabatic compressed air energy storage (SPV-A-CAES) system designed for the Chinhoyi University of Technology (CUT) Farm in Zimbabwe. Only the operation stage is quantified, so the paper does not claim a cradle-to-grave footprint. The functional unit is 1 kWh of electricity delivered and the project life is 25 years. The system combines a 225 kWp PV array with a two-stage intercooled compressor, thermal energy storage, above-ground air vessels and a radial-inflow turbine generator, at a vendor-quoted capital cost of USD 100,000. Dynamic simulation gives a round-trip efficiency of 67.8%, up from a 49.0% diabatic baseline. On the harmonized operating basis of 1,400 h/yr the system delivers 126,000 kWh per year, or 3.15 GWh over its life. The underlying project reports 1,850 tCO2-eq of avoided emissions against a diesel baseline. That equals 74 tCO2-eq per year and an average avoided intensity of 0.587 kg CO2-eq/kWh, or about 77% displacement of a diesel generator emitting 0.76 kg CO2/kWh. This figure is inherited from the project and has not been validated against measured diesel records, which were not available for this study. A bottom-up check shows that it is physically possible, at 66% to 88% of the full-displacement ceiling, and that it implies about 27,600 L of diesel per year, which farm fuel records can confirm or contradict. A threshold analysis shows that up-front emissions would have to exceed 1,850 tCO2-eq, at the reported rate, before the carbon payback time passed the project life, and an indicative allowance for upstream PV emissions keeps about 88% of the avoided emissions. Because component-level inventories are not yet available, the paper sets out a quantitative screening baseline and a data-collection protocol for a full assessment under ISO 14040 and 14044.

Authors

Institutions

Publication Details

Journal
International Journal of Latest Technology in Engineering Management & Applied Science
Published
2026-11-24
DOI
https://doi.org/10.51583/ijltemas.2026.151100031
Primary Topic
Photovoltaic Systems and Sustainability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Life-Cycle Environmental Assessment of a 90kW Solar Photovoltaic Adiabatic Compressed Air Energy Storage System (SPV-A-CAES) for Agricultural Electrification

Downmore Musademba, Peter Matarauka
International Journal of Latest Technology in Engineering Management & Applied Science
Photovoltaic Systems and Sustainability
article

Life-Cycle Environmental Assessment of a 90kW Solar Photovoltaic Adiabatic Compressed Air Energy Storage System (SPV-A-CAES) for Agricultural Electrification

Downmore Musademba, Peter Matarauka
article en

Abstract

This paper presents a screening life-cycle environmental assessment of a 90 kW solar photovoltaic adiabatic compressed air energy storage (SPV-A-CAES) system designed for the Chinhoyi University of Technology (CUT) Farm in Zimbabwe. Only the operation stage is quantified, so the paper does not claim a cradle-to-grave footprint. The functional unit is 1 kWh of electricity delivered and the project life is 25 years. The system combines a 225 kWp PV array with a two-stage intercooled compressor, thermal energy storage, above-ground air vessels and a radial-inflow turbine generator, at a vendor-quoted capital cost of USD 100,000. Dynamic simulation gives a round-trip efficiency of 67.8%, up from a 49.0% diabatic baseline. On the harmonized operating basis of 1,400 h/yr the system delivers 126,000 kWh per year, or 3.15 GWh over its life. The underlying project reports 1,850 tCO2-eq of avoided emissions against a diesel baseline. That equals 74 tCO2-eq per year and an average avoided intensity of 0.587 kg CO2-eq/kWh, or about 77% displacement of a diesel generator emitting 0.76 kg CO2/kWh. This figure is inherited from the project and has not been validated against measured diesel records, which were not available for this study. A bottom-up check shows that it is physically possible, at 66% to 88% of the full-displacement ceiling, and that it implies about 27,600 L of diesel per year, which farm fuel records can confirm or contradict. A threshold analysis shows that up-front emissions would have to exceed 1,850 tCO2-eq, at the reported rate, before the carbon payback time passed the project life, and an indicative allowance for upstream PV emissions keeps about 88% of the avoided emissions. Because component-level inventories are not yet available, the paper sets out a quantitative screening baseline and a data-collection protocol for a full assessment under ISO 14040 and 14044.

International Journal of Latest Technology in Engineering Management & Applied ScienceVol. 15(11)
Chinhoyi University of Technology (ZW)
Photovoltaic Systems and Sustainability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon