The adaptability of anammox enhanced anoxic/oxic/oxic/anoxic process to hydraulic retention time in treating simulated pretreated municipal wastewater based on its performance and mechanisms

Hydraulic retention time (HRT) is a significant operational parameter of bioreactors, which significantly affects the biochemical reaction time of the pollutants, thereby affecting their removal. Thus, the optimal HRT of a novel anammox enhanced anoxic/oxic/oxic/anoxic process was explored, and its adaptability to reducing HRT from 8 to 3 h was evaluated. This process was employed to remove carbon (C), nitrogen (N) and phosphorus (P) from simulated pretreated municipal wastewater with approximately 70% chemical oxygen demand (COD) removal. The average total phosphorus (TP) in the filtered effluent gradually decreased from 0.032 mg/L at the HRT of 8 h to 0.027 mg/L at the HRT of 3 h, and its removal rate increased from 99.39% to 99.48%, attributed to the chemical P removal through the formation of Mn 3 (PO 4) 2. While the average COD and filtered total nitrogen (TN) in the effluent increased from 5.53 and 0.68 to 10.59 and 5.79 mg/L, and their removal rate decreased from 93.94% and 98.90% to 88.40% and 90.68%, respectively. Their removal first slightly decreased when HRT decreased from 8 to 4 h, followed by a rapid decrease of the TN removal, but the COD removal slightly increased, attributed to the further acclimation of the hydrolytic bacteria. Anammox enhanced the N removal and the adaptability to the HRTs through partial denitrification-anammox and partial nitrification-anammox. The hydrolysis of the refractory organic matters and dead microorganisms provided more carbon source and improved the C and N removal, and biogenic manganese oxides enhanced the C removal. The identified functional bacteria and genes involved in hydrolysis, nitrification, denitrification and anammox revealed the removal pathways and mechanisms of C and N, and explained the strong adaptability to the HRTs. This process efficiently removed C, N and P, and had a strong adaptability to the HRTs.

Authors

Institutions

Publication Details

Journal
Frontiers in Microbiology
Published
2026-11-25
DOI
https://doi.org/10.3389/fmicb.2026.1991098
Primary Topic
Wastewater Treatment and Nitrogen Removal
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The adaptability of anammox enhanced anoxic/oxic/oxic/anoxic process to hydraulic retention time in treating simulated pretreated municipal wastewater based on its performance and mechanisms

Qingfeng Cheng, Erdeng Du, Lichao Nengzi, Huiyun Zhong et al.
Frontiers in Microbiology
Wastewater Treatment and Nitrogen Removal
article

The adaptability of anammox enhanced anoxic/oxic/oxic/anoxic process to hydraulic retention time in treating simulated pretreated municipal wastewater based on its performance and mechanisms

Qingfeng Cheng, Erdeng Du, Lichao Nengzi, Huiyun Zhong, Mingguo Peng, Tianyu Zhou, Yixin Lu, Chao Liu, Wenxing Zhao
article en

Abstract

Hydraulic retention time (HRT) is a significant operational parameter of bioreactors, which significantly affects the biochemical reaction time of the pollutants, thereby affecting their removal. Thus, the optimal HRT of a novel anammox enhanced anoxic/oxic/oxic/anoxic process was explored, and its adaptability to reducing HRT from 8 to 3 h was evaluated. This process was employed to remove carbon (C), nitrogen (N) and phosphorus (P) from simulated pretreated municipal wastewater with approximately 70% chemical oxygen demand (COD) removal. The average total phosphorus (TP) in the filtered effluent gradually decreased from 0.032 mg/L at the HRT of 8 h to 0.027 mg/L at the HRT of 3 h, and its removal rate increased from 99.39% to 99.48%, attributed to the chemical P removal through the formation of Mn 3 (PO 4) 2. While the average COD and filtered total nitrogen (TN) in the effluent increased from 5.53 and 0.68 to 10.59 and 5.79 mg/L, and their removal rate decreased from 93.94% and 98.90% to 88.40% and 90.68%, respectively. Their removal first slightly decreased when HRT decreased from 8 to 4 h, followed by a rapid decrease of the TN removal, but the COD removal slightly increased, attributed to the further acclimation of the hydrolytic bacteria. Anammox enhanced the N removal and the adaptability to the HRTs through partial denitrification-anammox and partial nitrification-anammox. The hydrolysis of the refractory organic matters and dead microorganisms provided more carbon source and improved the C and N removal, and biogenic manganese oxides enhanced the C removal. The identified functional bacteria and genes involved in hydrolysis, nitrification, denitrification and anammox revealed the removal pathways and mechanisms of C and N, and explained the strong adaptability to the HRTs. This process efficiently removed C, N and P, and had a strong adaptability to the HRTs.

Frontiers in MicrobiologyVol. 17
Xichang University (CN), Changzhou University (CN), Chengdu Technological University (CN)
Wastewater Treatment and Nitrogen Removal
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.