PAMAM-Calix-Dendrimer-Based Electrochemical Sensor for Determination of Sodium Dodecyl Sulfate Desorbed from Microplastics

Microplastics are persistent and widespread environmental pollutants whose impact extends beyond the particles themselves: their ability to sorb, transport, and release organic contaminants underlies the so-called “Trojan horse” effect. In this work, an electrochemical sensor was developed using second- and third-generation dendrimers with a macrocyclic core bearing poly(amidoamine) dendrons (PAMAM-calix-dendrimers) and terminal pyridylamide or benzamide groups. The dendrimers were immobilized on carbon black-modified glassy carbon electrodes and examined by cyclic and differential pulse voltammetry using ferrocyanide as a redox marker. The pH-dependent response of the benzamide derivatives was consistent with hydrophobic gating, whereas the third-generation pyridylamide derivative layer remained permeable to the marker over a broad pH range and responded strongly to both polyanionic sodium polystyrene sulfonate and amphiphilic sodium dodecyl sulfate. Spectroscopic measurements and dynamic light scattering showed ferrocyanide-induced supramolecular aggregation of the third-generation pyridylamide derivative, consistent with multivalent electrostatic cross-linking. The three calibration regions were described within a model of successive host–guest binding, surface adsorption and hemimicelle formation. The sensor exhibited an SDS response over the concentration range of 0.1 pM–1 mM, with a calculated detection limit of 79 fM obtained using the 3σ criterion. SDS desorbed from washed polyvinyl chloride microparticles was determined without preconcentration. The developed sensor was applied to the electrochemical determination of surfactants released from microplastics.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-11-24
DOI
https://doi.org/10.3390/s26237425
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

PAMAM-Calix-Dendrimer-Based Electrochemical Sensor for Determination of Sodium Dodecyl Sulfate Desorbed from Microplastics

Падня Павел Леонидович, Olga A. Mostovaya, Dmitry I. Stoikov, Igor Shiabiev et al.
Sensors
Electrochemical sensors and biosensors
article

PAMAM-Calix-Dendrimer-Based Electrochemical Sensor for Determination of Sodium Dodecyl Sulfate Desorbed from Microplastics

Падня Павел Леонидович, Olga A. Mostovaya, Dmitry I. Stoikov, Igor Shiabiev, Dominika Kappo, Ivan I. Stoikov, Kamila R. Karaguzina, Anastasia Sergeeva
article en

Abstract

Microplastics are persistent and widespread environmental pollutants whose impact extends beyond the particles themselves: their ability to sorb, transport, and release organic contaminants underlies the so-called “Trojan horse” effect. In this work, an electrochemical sensor was developed using second- and third-generation dendrimers with a macrocyclic core bearing poly(amidoamine) dendrons (PAMAM-calix-dendrimers) and terminal pyridylamide or benzamide groups. The dendrimers were immobilized on carbon black-modified glassy carbon electrodes and examined by cyclic and differential pulse voltammetry using ferrocyanide as a redox marker. The pH-dependent response of the benzamide derivatives was consistent with hydrophobic gating, whereas the third-generation pyridylamide derivative layer remained permeable to the marker over a broad pH range and responded strongly to both polyanionic sodium polystyrene sulfonate and amphiphilic sodium dodecyl sulfate. Spectroscopic measurements and dynamic light scattering showed ferrocyanide-induced supramolecular aggregation of the third-generation pyridylamide derivative, consistent with multivalent electrostatic cross-linking. The three calibration regions were described within a model of successive host–guest binding, surface adsorption and hemimicelle formation. The sensor exhibited an SDS response over the concentration range of 0.1 pM–1 mM, with a calculated detection limit of 79 fM obtained using the 3σ criterion. SDS desorbed from washed polyvinyl chloride microparticles was determined without preconcentration. The developed sensor was applied to the electrochemical determination of surfactants released from microplastics.

SensorsVol. 26(23)
Kazan Federal University (RU)
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon