Comparison of Classical Image Processing Methods and the Artificial Intelligence-Based MedSAM2 Model for Liver Tumor Segmentation in Radioembolization Dosimetry: A LiTS Dataset Analysis
Objectives: Accurate estimation of tumor and critical organ doses in radioembolization therapy is essential for treatment planning. The choice of segmentation technique used in voxel-based dosimetry can affect the calculated volumes and dose estimates. In this study, the liver tumor segmentation performances of classical image processing methods and a pretrained artificial intelligence (AI) Medical Segment Anything Model 2 (MedSAM2) were compared, along with their effects on a simplified dose-change indicator. Methods: From the 131 training cases in the Liver Tumor Segmentation Benchmark dataset, 33 eligible cases were identified using previously published radioembolization eligibility criteria; of these, 30 patients were selected by tumor-volume-stratified sampling. In each patient, four classical methods [dilation, erosion, region of interest (ROI)-based Otsu thresholding, ROI-based K-means clustering] and one AI-based method (MedSAM2) were applied to the reference tumor mask, and the resulting volumes were compared with the reference volume to calculate a simplified medical internal radiation dosimetry-derived dose-change percentage. Results: All five methods were successfully completed in all 30 patients. Mean±standard deviation (median) dose-change percentages were -25.5%±8.9% (-25.3%) for dilation, 50.9%±30.2% (43.1%) for erosion, 177.3%±1324.8% (-78.3%) for ROI-thresholding, -65.0%±33.0% (-79.0%) for ROI-K-means, and -30.2%±40.7% (-34.6%) for MedSAM2. ROI-thresholding produced an extreme deviation (7189.2%) in one patient due to a degenerate threshold; MedSAM2 showed a similar extreme deviation (-99.2%) in one patient by segmenting an area approximately 123-fold the reference volume. Excluding these outliers, MedSAM2's variance remained lower than that of the classical thresholding and clustering methods. Conclusion: The choice of liver tumor segmentation method can lead to differences ranging from 10% to over 1000% in simplified dose estimates. Classical thresholding and clustering methods tend to produce infrequent but severe outliers, whereas a pretrained AI model (MedSAM2) yields more stable results, although it is not entirely error-free. These findings point to the importance of standardizing and reporting the segmentation method used in pre-treatment dosimetric assessment for radioembolization.
Authors
- Özlem Maranci Yıldırım
Publication Details
- Journal
- Molecular Imaging and Radionuclide Therapy
- Published
- 2026-11-25
- DOI
- https://doi.org/10.4274/mirt.galenos.2026.56578
- Primary Topic
- Medical Image Segmentation Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00