Resilience assessment and differentiated management of a heat-cold island network for heat risk mitigation in a valley city

Global warming and rapid urbanization have intensified urban heat risks, while valley cities face additional challenges because topographic constraints can impede the spatial transfer of cooling effects. However, existing studies have paid limited attention to the resilience responses of heat-cold island network (HCIN) to corridor disturbances and their differentiated management, limiting targeted urban heat-risk management. Taking the main urban area of Lanzhou, a typical valley city, as a case study, this study constructed a HCIN and integrated resilience assessment with differentiated spatial management to reveal its structural characteristics, disturbance responses, and differentiated spatial intervention and management needs. The results showed that, jointly driven by changes in heat-cold island patterns and resistance surfaces, the HCIN underwent substantial structural changes from 2005 to 2023. Under deliberate attack (DA), structural resilience (SR) declined rapidly at low removal rates, whereas under random attack (RA), SR exhibited a cumulative decline at moderate-to-high removal rates. Functional resilience (FR) was more sensitive to DA and remained at a low level under both DA and RA at high removal rates. By further integrating corridor contributions to network resilience with changes in corridor resistance, the corridors were classified into seven differentiated types: critical resistance-increase, important resistance-increase, important resistance-decrease, important resistance-stable, general resistance-increase, general resistance-decrease, and general resistance-stable corridors, based on which targeted spatial management strategies were proposed. This study integrates HCIN resilience assessment and differentiated management into urban heat-risk mitigation and proposes differentiated management strategies for HCIN corridors for heat-risk regulation. It provides methodological support for shifting urban heat-risk mitigation from static pattern identification toward resilience assessment and differentiated regulation, while offering a reference for cities facing similar heat-risk challenges.

Authors

Institutions

Publication Details

Journal
Ecological Indicators
Published
2026-11-25
DOI
https://doi.org/10.1016/j.ecolind.2026.115908
Primary Topic
Urban Heat Island Mitigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Resilience assessment and differentiated management of a heat-cold island network for heat risk mitigation in a valley city

Xin Jin, Xufeng Mao, Junfeng Yin, wanfeng Su et al.
Ecological Indicators
Urban Heat Island Mitigation
article

Resilience assessment and differentiated management of a heat-cold island network for heat risk mitigation in a valley city

Xin Jin, Xufeng Mao, Junfeng Yin, wanfeng Su, JIN Yanxiang, LI Ziang, Haoyuan Feng, Xuehong Li, Zhifeng Liu
article en

Abstract

Global warming and rapid urbanization have intensified urban heat risks, while valley cities face additional challenges because topographic constraints can impede the spatial transfer of cooling effects. However, existing studies have paid limited attention to the resilience responses of heat-cold island network (HCIN) to corridor disturbances and their differentiated management, limiting targeted urban heat-risk management. Taking the main urban area of Lanzhou, a typical valley city, as a case study, this study constructed a HCIN and integrated resilience assessment with differentiated spatial management to reveal its structural characteristics, disturbance responses, and differentiated spatial intervention and management needs. The results showed that, jointly driven by changes in heat-cold island patterns and resistance surfaces, the HCIN underwent substantial structural changes from 2005 to 2023. Under deliberate attack (DA), structural resilience (SR) declined rapidly at low removal rates, whereas under random attack (RA), SR exhibited a cumulative decline at moderate-to-high removal rates. Functional resilience (FR) was more sensitive to DA and remained at a low level under both DA and RA at high removal rates. By further integrating corridor contributions to network resilience with changes in corridor resistance, the corridors were classified into seven differentiated types: critical resistance-increase, important resistance-increase, important resistance-decrease, important resistance-stable, general resistance-increase, general resistance-decrease, and general resistance-stable corridors, based on which targeted spatial management strategies were proposed. This study integrates HCIN resilience assessment and differentiated management into urban heat-risk mitigation and proposes differentiated management strategies for HCIN corridors for heat-risk regulation. It provides methodological support for shifting urban heat-risk mitigation from static pattern identification toward resilience assessment and differentiated regulation, while offering a reference for cities facing similar heat-risk challenges.

Ecological IndicatorsVol. 193
Qinghai Normal University (CN), Beijing Normal University (CN), Northwest Normal University (CN), Shaanxi Normal University (CN)
Urban Heat Island Mitigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon