Original thermodynamic cycle, experimental compression test and numerical simulation of thermal losses of a hydro-CO2 heat pump for high temperature applications

High temperature heat pumps (HTHPs) are expected to highly contribute to industrial decarbonation. As current state-of-the-art technologies do not cover sufficiently wide temperature ranges and have limited exergy efficiency, a novel CO 2 heat pump, where compression and expansion transformations are achieved with a hydraulic piston, was developed to minimize exergy losses. This paper studies a novel architecture that is designed for exergy loss minimization. Theoretically, the hydro-CO 2 heat pump enables isochoric, isentropic, quasi-isothermal transformations and novel thermodynamic cycles. To describe this novel cycle, a numerical model details the performance in ideal conditions and shows maximal COPs of 1.82 at the heat source and 2.76 at the heat sink with a temperature lift of 187 K. To evaluate exergy losses on a real system, a laboratory-scale prototype was developed. Experimental results show that standard compressions achieved with the hydro-CO 2 system are far from the isentropic isoline, with an isentropic performance of 15.6%, mainly because of heat losses. Those heat losses are estimated with an additional numerical model, which is validated with the experimental data. The final simulations show that upscaling the prototype towards greater dimensions and reducing the compression time by a factor 10 allows to reach an isentropic performance of 87.3% without improving insulation solutions. The provided conclusions validate the hydro-CO 2 heat pump potential to provide better compression solutions.

Authors

Institutions

Publication Details

Journal
Applied Thermal Engineering
Published
2026-11-25
DOI
https://doi.org/10.1016/j.applthermaleng.2026.134143
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Original thermodynamic cycle, experimental compression test and numerical simulation of thermal losses of a hydro-CO2 heat pump for high temperature applications

Olivier Thomé, Paul Byrne, François Faraldo
Applied Thermal Engineering
Refrigeration and Air Conditioning Technologies
article

Original thermodynamic cycle, experimental compression test and numerical simulation of thermal losses of a hydro-CO2 heat pump for high temperature applications

Olivier Thomé, Paul Byrne, François Faraldo
article en

Abstract

High temperature heat pumps (HTHPs) are expected to highly contribute to industrial decarbonation. As current state-of-the-art technologies do not cover sufficiently wide temperature ranges and have limited exergy efficiency, a novel CO 2 heat pump, where compression and expansion transformations are achieved with a hydraulic piston, was developed to minimize exergy losses. This paper studies a novel architecture that is designed for exergy loss minimization. Theoretically, the hydro-CO 2 heat pump enables isochoric, isentropic, quasi-isothermal transformations and novel thermodynamic cycles. To describe this novel cycle, a numerical model details the performance in ideal conditions and shows maximal COPs of 1.82 at the heat source and 2.76 at the heat sink with a temperature lift of 187 K. To evaluate exergy losses on a real system, a laboratory-scale prototype was developed. Experimental results show that standard compressions achieved with the hydro-CO 2 system are far from the isentropic isoline, with an isentropic performance of 15.6%, mainly because of heat losses. Those heat losses are estimated with an additional numerical model, which is validated with the experimental data. The final simulations show that upscaling the prototype towards greater dimensions and reducing the compression time by a factor 10 allows to reach an isentropic performance of 87.3% without improving insulation solutions. The provided conclusions validate the hydro-CO 2 heat pump potential to provide better compression solutions.

Applied Thermal EngineeringVol. 311
Laboratoire de génie civil et génie mécanique (FR), Université de Rennes (FR)
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon