Evaluating the Defect Performance of Panelized and Modular Systems in a Live House Construction Research Project †

Modern methods of construction (MMCs) are often embraced by many countries as opportunities to fuel economies and resolve accommodation shortages, by and large due to assertions that they offer economic advantages, including superior quality performance. Contractors and manufacturers see them as prospects to enter new markets and generate profits. While practitioners and scholars have argued for the better overall economic performance of MMCs, insisting on their superior quality performance, it is accepted that the arguments presented in the published literature lack empirical substantiation. As a result, end users typically do not have the data required to make informed decisions. This article informs, among other relevant actors, end users and governments by evaluating a key aspect of quality performance, that is, the defect performance of four MMCs, namely, steel frame and concrete panelized construction methods, and steel- and timber-based modular construction systems, in one live house construction research experiment overseen by a single construction company on a building site with identical soil conditions, involving houses with similar or identical designs. The methodology included analyses of the building designs and defect data, and interviews with relevant construction personnel. The research findings revealed that some MMCs resulted in a higher number and more consequential defects than traditionally built houses. The light-gauge steel frame panelized construction system resulted in the lowest quantity of defects (4.07 defects per house), followed closely by the traditional construction method (4.50 per house). The steel frame modular type one construction system and the concrete panelized construction system resulted in the highest overall quantity of defects, respectively, 8.38 and 8.50 per house. The steel frame modular construction system type two resulted in significantly fewer defects (4.83 per house) compared to its identical counterpart, namely, the type one steel frame modular construction system. These revelations are important in the context of the inadequate durability and whole-life quality performance measurements of MMCs, which are likely to impact the desirability and sustainability of MMCs.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-11-25
DOI
https://doi.org/10.3390/buildings16234730
Primary Topic
BIM and Construction Integration
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Evaluating the Defect Performance of Panelized and Modular Systems in a Live House Construction Research Project †

Vasil Angelov Atanasov
Buildings
BIM and Construction Integration
article

Evaluating the Defect Performance of Panelized and Modular Systems in a Live House Construction Research Project †

Vasil Angelov Atanasov
article en

Abstract

Modern methods of construction (MMCs) are often embraced by many countries as opportunities to fuel economies and resolve accommodation shortages, by and large due to assertions that they offer economic advantages, including superior quality performance. Contractors and manufacturers see them as prospects to enter new markets and generate profits. While practitioners and scholars have argued for the better overall economic performance of MMCs, insisting on their superior quality performance, it is accepted that the arguments presented in the published literature lack empirical substantiation. As a result, end users typically do not have the data required to make informed decisions. This article informs, among other relevant actors, end users and governments by evaluating a key aspect of quality performance, that is, the defect performance of four MMCs, namely, steel frame and concrete panelized construction methods, and steel- and timber-based modular construction systems, in one live house construction research experiment overseen by a single construction company on a building site with identical soil conditions, involving houses with similar or identical designs. The methodology included analyses of the building designs and defect data, and interviews with relevant construction personnel. The research findings revealed that some MMCs resulted in a higher number and more consequential defects than traditionally built houses. The light-gauge steel frame panelized construction system resulted in the lowest quantity of defects (4.07 defects per house), followed closely by the traditional construction method (4.50 per house). The steel frame modular type one construction system and the concrete panelized construction system resulted in the highest overall quantity of defects, respectively, 8.38 and 8.50 per house. The steel frame modular construction system type two resulted in significantly fewer defects (4.83 per house) compared to its identical counterpart, namely, the type one steel frame modular construction system. These revelations are important in the context of the inadequate durability and whole-life quality performance measurements of MMCs, which are likely to impact the desirability and sustainability of MMCs.

BuildingsVol. 16(23)
Robert Gordon University (GB)
BIM and Construction Integration
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon