Automated CTA-Based Assessment of Aortic Remodeling Through Volumetric Biomarkers in Type B Aortic Dissection

Type B aortic dissection (TBAD) requires lifelong morphological monitoring using computed tomography angiography (CTA). TBAD separates blood flow into the true lumen (TL), the original aortic channel, and the false lumen (FL), created by the dissection. Although three-dimensional volumetric analysis may complement diameter-based surveillance, its clinical adoption is limited by the time required for manual segmentation, particularly in postoperative scans affected by metallic artifacts. This study developed and evaluated an automated CTA-based framework for volumetric surveillance of TBAD across native and post-TEVAR conditions. We propose AORTA-SCAN, a hierarchical multi-stage framework for automated segmentation of the aorta, TL, and FL, extended to stented anatomy through a metal-aware triple-input strategy. The system computes conventional diameter measurements and volumetric biomarkers, including the perfusion dissection index (PDI), defined as the ratio between perfused FL volume and total perfused aortic volume. Domain adaptation was achieved using transfer learning and partial-label learning across heterogeneous clinical annotations. In native cases, AORTA-SCAN achieved a global Dice score of 0.84 and significantly improved FL segmentation compared with the nnU-Net baseline (0.84 vs 0.71, p < 0.001). Volumetric analysis showed high agreement with expert references, with a mean PDI bias of -0.17%. In postoperative cases, TL segmentation remained robust (Dice = 0.90), while FL and stent Dice were 0.75 and 0.72, respectively. Processing was completed in less than 1 minute per case on a standard workstation. AORTA-SCAN enables automated volumetric surveillance of TBAD and supports scalable extraction of PDI and diameter biomarkers from native and post-TEVAR CTA.

Authors

Institutions

Publication Details

Journal
medRxiv
Published
2026-11-24
DOI
https://doi.org/10.64898/2026.11.23.26368738
Primary Topic
Aortic Disease and Treatment Approaches
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Automated CTA-Based Assessment of Aortic Remodeling Through Volumetric Biomarkers in Type B Aortic Dissection

Luca Tommaso Mainardi, Marco Ferraresi, Giovanni Rossi, Pietro Cerveri et al.
medRxiv
Aortic Disease and Treatment Approaches
preprint

Automated CTA-Based Assessment of Aortic Remodeling Through Volumetric Biomarkers in Type B Aortic Dissection

Luca Tommaso Mainardi, Marco Ferraresi, Giovanni Rossi, Pietro Cerveri, Alice Maccarini, Janko Jovanovic, Alessandro Molinari
preprint en

Abstract

Type B aortic dissection (TBAD) requires lifelong morphological monitoring using computed tomography angiography (CTA). TBAD separates blood flow into the true lumen (TL), the original aortic channel, and the false lumen (FL), created by the dissection. Although three-dimensional volumetric analysis may complement diameter-based surveillance, its clinical adoption is limited by the time required for manual segmentation, particularly in postoperative scans affected by metallic artifacts. This study developed and evaluated an automated CTA-based framework for volumetric surveillance of TBAD across native and post-TEVAR conditions. We propose AORTA-SCAN, a hierarchical multi-stage framework for automated segmentation of the aorta, TL, and FL, extended to stented anatomy through a metal-aware triple-input strategy. The system computes conventional diameter measurements and volumetric biomarkers, including the perfusion dissection index (PDI), defined as the ratio between perfused FL volume and total perfused aortic volume. Domain adaptation was achieved using transfer learning and partial-label learning across heterogeneous clinical annotations. In native cases, AORTA-SCAN achieved a global Dice score of 0.84 and significantly improved FL segmentation compared with the nnU-Net baseline (0.84 vs 0.71, p < 0.001). Volumetric analysis showed high agreement with expert references, with a mean PDI bias of -0.17%. In postoperative cases, TL segmentation remained robust (Dice = 0.90), while FL and stent Dice were 0.75 and 0.72, respectively. Processing was completed in less than 1 minute per case on a standard workstation. AORTA-SCAN enables automated volumetric surveillance of TBAD and supports scalable extraction of PDI and diameter biomarkers from native and post-TEVAR CTA.

medRxiv
University of Pavia (IT), Alessandro Manzoni Hospital (IT), Aziende Socio Sanitarie Territoriali di Lecco (IT), Politecnico di Milano (IT)
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon