Quality Assessment of Drinking Groundwater in Anasora Woreda, Ethiopia

Background and Objective: Drinking water should be free unwanted constituent, contaminant, or impurity and fulfill quality requirements (desirable and permissible limits) recommended national and international organizations. This study evaluated the quality of drinking groundwater in selected Kebeles of Ana Sora District, Guji Zone, Oromia Regional State, Ethiopia, by analyzing physicochemical parameters, minerals, trace elements, and heavy metals. Materials and Methods: Groundwater samples were collected from selected Kebeles of Ana Sora District, Ethiopia. Temperature, pH, electrical conductivity (EC), and total dissolved solids (TDS) were measured using an AD8000 pH/mV/EC/TDS/Temp meter. Total hardness (TH), total alkalinity (TA), and chloride were determined using titration methods. Calcium (Ca), Magnesium (Mg), Copper (Cu), Manganese (Mn), Nickel (Ni), Cobalt (Co), Chromium (Cr), and Lead (Pb) concentrations were analyzed using Flame Atomic Absorption Spectrometry (FAAS). The obtained results were compared with the acceptable limits specified in the Compulsory Ethiopian Drinking Water Specifications. One-way Analysis of Variance (ANOVA) for the heavy metal dataset was performed to determine significant differences among the groundwater samples, with statistical significance set at p<0.05. Results: The average values of the physicochemical parameters investigated in this study were found to be in the range: Temperature (20.8-23.1) °C, pH (6.6-7.1), EC (23.7-48.0) μS/cm, TDS (8.5-24.5) mg/L, TH (14.7-42.4) mg/L, TA (23.3-38.3) mg/L and chloride (2.3-3.8) mg/L. The mean concentrations of the minerals were found to be in the range: Ca (2.32-9.62) mg/L, Mg (11.9-19.7) mg/L, and Cu (0.13-0.30) mg/L. Metals such as Mn, Ni, Co, Cr, and Pb were found to be below the detection limit of the instrument. One-way-ANOVA analysis showed that there were significant variations (p<0.05) in the quantified metal among the drinking groundwater samples. Conclusion: Groundwater quality in the Ana Sora District complied with the Compulsory Ethiopian Drinking Water Specifications (CES 58:2019) for all investigated physicochemical parameters and heavy metals. The soft water, near-neutral pH, low salinity, and non-detectable toxic trace metals (

Authors

Institutions

Publication Details

Journal
Asian Journal of Biological Sciences
Published
2026-11-25
DOI
https://doi.org/10.3923/ajbs.2026.150.163
Primary Topic
Water Quality and Pollution Assessment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Quality Assessment of Drinking Groundwater in Anasora Woreda, Ethiopia

Melaku Zigde Haile, Ararso Dereje Janbo
Asian Journal of Biological Sciences
Water Quality and Pollution Assessment
article

Quality Assessment of Drinking Groundwater in Anasora Woreda, Ethiopia

Melaku Zigde Haile, Ararso Dereje Janbo
article en

Abstract

Background and Objective: Drinking water should be free unwanted constituent, contaminant, or impurity and fulfill quality requirements (desirable and permissible limits) recommended national and international organizations. This study evaluated the quality of drinking groundwater in selected Kebeles of Ana Sora District, Guji Zone, Oromia Regional State, Ethiopia, by analyzing physicochemical parameters, minerals, trace elements, and heavy metals. Materials and Methods: Groundwater samples were collected from selected Kebeles of Ana Sora District, Ethiopia. Temperature, pH, electrical conductivity (EC), and total dissolved solids (TDS) were measured using an AD8000 pH/mV/EC/TDS/Temp meter. Total hardness (TH), total alkalinity (TA), and chloride were determined using titration methods. Calcium (Ca), Magnesium (Mg), Copper (Cu), Manganese (Mn), Nickel (Ni), Cobalt (Co), Chromium (Cr), and Lead (Pb) concentrations were analyzed using Flame Atomic Absorption Spectrometry (FAAS). The obtained results were compared with the acceptable limits specified in the Compulsory Ethiopian Drinking Water Specifications. One-way Analysis of Variance (ANOVA) for the heavy metal dataset was performed to determine significant differences among the groundwater samples, with statistical significance set at p<0.05. Results: The average values of the physicochemical parameters investigated in this study were found to be in the range: Temperature (20.8-23.1) °C, pH (6.6-7.1), EC (23.7-48.0) μS/cm, TDS (8.5-24.5) mg/L, TH (14.7-42.4) mg/L, TA (23.3-38.3) mg/L and chloride (2.3-3.8) mg/L. The mean concentrations of the minerals were found to be in the range: Ca (2.32-9.62) mg/L, Mg (11.9-19.7) mg/L, and Cu (0.13-0.30) mg/L. Metals such as Mn, Ni, Co, Cr, and Pb were found to be below the detection limit of the instrument. One-way-ANOVA analysis showed that there were significant variations (p<0.05) in the quantified metal among the drinking groundwater samples. Conclusion: Groundwater quality in the Ana Sora District complied with the Compulsory Ethiopian Drinking Water Specifications (CES 58:2019) for all investigated physicochemical parameters and heavy metals. The soft water, near-neutral pH, low salinity, and non-detectable toxic trace metals (

Asian Journal of Biological SciencesVol. 19(4)
Deen Dayal Upadhyaya Gorakhpur University (IN)
Water Quality and Pollution Assessment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon