More gas-pressure-held columns: a barrier-discharge filament, a fluorescent-lamp column and an air circuit-breaker arc

This working note applies the Bennett (1934) pinch relation, as used in the Kirk Axial Pinch Theory, to three more published laboratory measurements of glowing gas columns. The formula gives the current a straight column would need for its own magnetic squeeze to hold back the gas pressure in it. For a single barrier-discharge filament in open air (Vanraes et al. 2018), the measured current is about 3,630 times smaller than that. For a low-pressure argon–mercury lamp column (Bakker & Kroesen 2000), it is about 5,140 times smaller at the fill pressure, and at least 55 times smaller on electron pressure alone. For a 1.8 kA air arc in a laboratory breaker model (Becerra et al. 2019), it is at least 2.9–4.2 times smaller, a lower bound. All pressures, ranges and caveats are stated plainly.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-24
DOI
https://doi.org/10.5281/zenodo.24521345
Primary Topic
Vacuum and Plasma Arcs
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

More gas-pressure-held columns: a barrier-discharge filament, a fluorescent-lamp column and an air circuit-breaker arc

Kirk Bagger
Zenodo (CERN European Organization for Nuclear Research)
Vacuum and Plasma Arcs
article

More gas-pressure-held columns: a barrier-discharge filament, a fluorescent-lamp column and an air circuit-breaker arc

Kirk Bagger
article en

Abstract

This working note applies the Bennett (1934) pinch relation, as used in the Kirk Axial Pinch Theory, to three more published laboratory measurements of glowing gas columns. The formula gives the current a straight column would need for its own magnetic squeeze to hold back the gas pressure in it. For a single barrier-discharge filament in open air (Vanraes et al. 2018), the measured current is about 3,630 times smaller than that. For a low-pressure argon–mercury lamp column (Bakker & Kroesen 2000), it is about 5,140 times smaller at the fill pressure, and at least 55 times smaller on electron pressure alone. For a 1.8 kA air arc in a laboratory breaker model (Becerra et al. 2019), it is at least 2.9–4.2 times smaller, a lower bound. All pressures, ranges and caveats are stated plainly.

Zenodo (CERN European Organization for Nuclear Research)
Vacuum and Plasma Arcs
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon