Thermal–Fluid Analysis of Droplet Breakup in Steam‐Assisted Devolatilization Systems

In high‐temperature steam‐assisted devolatilization systems, effective breakup of polymer‐laden droplets is essential for enhancing heat and mass transfer. This study presents a computational fluid dynamics (CFD) investigation of droplet breakup and devolatilization in a steam contactor. A Lagrangian discrete‐phase model (DPM) coupled with the WAVE breakup model is employed to resolve droplet dynamics under high‐velocity steam flow. Three inlet parameters—polymer concentration, cement (polymer mixture) mass flow rate, and steam mass flow rate—are systematically varied to evaluate their influence on breakup behavior and devolatilization efficiency. The observed trends are interpreted using Weber–Ohnesorge scaling, in which steam flow governs aerodynamic breakup through the Weber number, whereas polymer concentration and cement loading influence viscous damping through an effective Ohnesorge number. Increasing polymer concentration enhances devolatilization and promotes finer droplet formation; however, excessive polymer loading suppresses fragmentation because of increased viscosity. The cement mass flow rate strongly affects droplet stability and aerodynamic interactions, with an intermediate flow rate of 44 t/h providing optimal breakup and devolatilization characteristics. Moderate steam loading improves breakup and volatile removal, whereas excessive steam flow promotes coalescence and larger droplets. An inlet steam rate of 13.6 t/h yields the most favorable balance between aerodynamic forcing and droplet resistance. Breakup and devolatilization behavior are quantified using the average outlet polymer mass fraction, breakup efficiency index (BEI), and particle size distribution (PSD). The study identifies an optimal operating window for industrial steam‐assisted devolatilization systems.

Authors

Institutions

Publication Details

Journal
Journal of Thermal Science and Engineering Applications
Published
2026-11-25
DOI
https://doi.org/10.1002/jtse.70007
Primary Topic
Fluid Dynamics and Heat Transfer
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Thermal–Fluid Analysis of Droplet Breakup in Steam‐Assisted Devolatilization Systems

Abhilash J. Chandy, Anand Kumar
Journal of Thermal Science and Engineering Applications
Fluid Dynamics and Heat Transfer
article

Thermal–Fluid Analysis of Droplet Breakup in Steam‐Assisted Devolatilization Systems

Abhilash J. Chandy, Anand Kumar
article en

Abstract

In high‐temperature steam‐assisted devolatilization systems, effective breakup of polymer‐laden droplets is essential for enhancing heat and mass transfer. This study presents a computational fluid dynamics (CFD) investigation of droplet breakup and devolatilization in a steam contactor. A Lagrangian discrete‐phase model (DPM) coupled with the WAVE breakup model is employed to resolve droplet dynamics under high‐velocity steam flow. Three inlet parameters—polymer concentration, cement (polymer mixture) mass flow rate, and steam mass flow rate—are systematically varied to evaluate their influence on breakup behavior and devolatilization efficiency. The observed trends are interpreted using Weber–Ohnesorge scaling, in which steam flow governs aerodynamic breakup through the Weber number, whereas polymer concentration and cement loading influence viscous damping through an effective Ohnesorge number. Increasing polymer concentration enhances devolatilization and promotes finer droplet formation; however, excessive polymer loading suppresses fragmentation because of increased viscosity. The cement mass flow rate strongly affects droplet stability and aerodynamic interactions, with an intermediate flow rate of 44 t/h providing optimal breakup and devolatilization characteristics. Moderate steam loading improves breakup and volatile removal, whereas excessive steam flow promotes coalescence and larger droplets. An inlet steam rate of 13.6 t/h yields the most favorable balance between aerodynamic forcing and droplet resistance. Breakup and devolatilization behavior are quantified using the average outlet polymer mass fraction, breakup efficiency index (BEI), and particle size distribution (PSD). The study identifies an optimal operating window for industrial steam‐assisted devolatilization systems.

Journal of Thermal Science and Engineering Applications
Indian Institute of Technology Bombay (IN)
Fluid Dynamics and Heat Transfer
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.