Independent evaluation of eight deep learning breast cancer detection algorithms as a second reader and for triage in a UK breast screening cohort

Objectives To benchmark commercial breast cancer detection algorithms for standalone reading, paired reading, and triage in a UK cohort. Materials and methods Digital mammograms were retrospectively collected from two UK Breast Screening Programme sites (Cambridge and Norwich; 2017), excluding mammograms without two-view images, 3-year follow-up, or algorithm scores. Eight algorithms from five companies were assessed at single-reader specificity as a standalone reader or paired with the first human reader, and in low- and high-suspicion triage scenarios. The reference standard was histopathologically confirmed cancer (screen-detected, interval, or next-round). Performance metrics included AUC, sensitivity, specificity, recall rate, and arbitration rate; noninferiority was assessed at a 5% margin. Results Of 22,778 mammograms (median age: 59 years; IQR: 54–63), 294 were screen-detected, 151 were interval, and 209 were next-round cancers. AUCs ranged 0.82–0.91; one algorithm was inferior to all others (p < 0.001). As a standalone reader, four algorithms had noninferior sensitivity (range: 47.2–64.5%) versus single reading (62.9%). Paired with the first reader, sensitivities were 64.7–67.4% (all but one noninferior to double reading: 67.9%) and specificities 97.5% (all superior to double reading: 97.1%; all p < 0.001). Low-suspicion triage ruled out 37.4–65.7% of mammograms, missing ≤ 1.0% of screen-detected cancers; high-suspicion triage ruled in 3.6–12.2% of interval and next-round cancers. In combined triage, sensitivity (68.8–71.2%) was superior to double reading for five algorithms and noninferior for the remainder. Conclusions Algorithms demonstrated variable standalone performance. When paired with a human reader, all but one were noninferior to double reading; in a combined triage workflow, all were noninferior and several had superior sensitivity. Key Points Question How do eight commercial deep learning algorithms from five vendors compare as standalone readers, paired with a single reader, and for triage in a UK breast screening cohort? Findings Most algorithms performed comparably and were noninferior in sensitivity to double reading when paired with a single reader, with one consistent underperformer; combined triage was noninferior or superior in sensitivity while maintaining specificity, at the cost of increased arbitration. Clinical relevance Commercial algorithms differ in performance, and newer versions are not necessarily better, supporting independent, head-to-head evaluation before prospective evaluation.

Authors

Institutions

Publication Details

Journal
European Radiology
Published
2026-11-25
DOI
https://doi.org/10.1007/s00330-026-12997-4
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Independent evaluation of eight deep learning breast cancer detection algorithms as a second reader and for triage in a UK breast screening cohort

Sarah E. Hickman, Fleur Kilburn‐Toppin, Richard T Black, Fiona J. Gilbert et al.
European Radiology
AI in cancer detection
article

Independent evaluation of eight deep learning breast cancer detection algorithms as a second reader and for triage in a UK breast screening cohort

Sarah E. Hickman, Fleur Kilburn‐Toppin, Richard T Black, Fiona J. Gilbert, Joshua Daniel Kaggie, Joshua Rothwell, Nicholas Roy Payne, Muzna Nanaa, Yuan Huang
article en

Abstract

Objectives To benchmark commercial breast cancer detection algorithms for standalone reading, paired reading, and triage in a UK cohort. Materials and methods Digital mammograms were retrospectively collected from two UK Breast Screening Programme sites (Cambridge and Norwich; 2017), excluding mammograms without two-view images, 3-year follow-up, or algorithm scores. Eight algorithms from five companies were assessed at single-reader specificity as a standalone reader or paired with the first human reader, and in low- and high-suspicion triage scenarios. The reference standard was histopathologically confirmed cancer (screen-detected, interval, or next-round). Performance metrics included AUC, sensitivity, specificity, recall rate, and arbitration rate; noninferiority was assessed at a 5% margin. Results Of 22,778 mammograms (median age: 59 years; IQR: 54–63), 294 were screen-detected, 151 were interval, and 209 were next-round cancers. AUCs ranged 0.82–0.91; one algorithm was inferior to all others (p < 0.001). As a standalone reader, four algorithms had noninferior sensitivity (range: 47.2–64.5%) versus single reading (62.9%). Paired with the first reader, sensitivities were 64.7–67.4% (all but one noninferior to double reading: 67.9%) and specificities 97.5% (all superior to double reading: 97.1%; all p < 0.001). Low-suspicion triage ruled out 37.4–65.7% of mammograms, missing ≤ 1.0% of screen-detected cancers; high-suspicion triage ruled in 3.6–12.2% of interval and next-round cancers. In combined triage, sensitivity (68.8–71.2%) was superior to double reading for five algorithms and noninferior for the remainder. Conclusions Algorithms demonstrated variable standalone performance. When paired with a human reader, all but one were noninferior to double reading; in a combined triage workflow, all were noninferior and several had superior sensitivity. Key Points Question How do eight commercial deep learning algorithms from five vendors compare as standalone readers, paired with a single reader, and for triage in a UK breast screening cohort? Findings Most algorithms performed comparably and were noninferior in sensitivity to double reading when paired with a single reader, with one consistent underperformer; combined triage was noninferior or superior in sensitivity while maintaining specificity, at the cost of increased arbitration. Clinical relevance Commercial algorithms differ in performance, and newer versions are not necessarily better, supporting independent, head-to-head evaluation before prospective evaluation.

European Radiology
Engineering and Physical Sciences Research Council (GB), Barts Health NHS Trust (GB), University of Cambridge (GB), Royal London Hospital (GB), Bolton NHS Foundation Trust (GB), Royal Bolton Hospital (GB)
AI in cancer detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon