End-Tidal Propofol Monitor Based on Deep Ultraviolet Fluorescence Spectroscopy Using Physics-Based Real-Time Correction and Deconvolution Models

Since the 2007 report of a correlation between exhaled and plasma propofol using proton transfer reaction mass spectrometry, there has been a desire to develop clinically acceptable exhaled propofol monitors that are compact, simple, practical, and economical. Since the propofol concentration in the breathing circuit during anesthesia fluctuates significantly every 5−10 s, monitors used in anesthesia practice require high time-resolution and highly sensitive measurements to enable continuous monitoring. Additionally, the composition of the gas sampled from the breathing circuit changes frequently due to bidirectional flow in the circuit, drastic changes in matrix composition between inhaled and exhaled airs, especially water vapor, and the adsorption and desorption of propofol on the inner surfaces. A propofol concentration waveform is also required to confirm measurement validity in clinical practice, similar to a capnometer that continuously displays high-resolution waveforms. In this study, we developed a fluorescence gas instrument with a time resolution of 10 Hz using deep ultraviolet LED excitation. We implemented a real-time algorithm to precisely calculate and correct background signal and fluorescence quenching using physical models, while monitoring major matrix components with auxiliary sensors. The end-tidal propofol concentration of every ventilation period was then determined by applying a first-order lag model to propofol in the sidestream sampling. We successfully demonstrated breath-by-breath detection sensitivity down to 0.3 ppb for end-tidal propofol concentration with minimal calibration, indicating that a non-invasive end-tidal propofol monitor as a medical device is feasible.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-11-25
DOI
https://doi.org/10.1021/acs.analchem.6c05093
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

End-Tidal Propofol Monitor Based on Deep Ultraviolet Fluorescence Spectroscopy Using Physics-Based Real-Time Correction and Deconvolution Models

Kenichi Masui, Takahiro Goto, Toshihide Hikida, Akio Shimono et al.
Analytical Chemistry
Advanced Chemical Sensor Technologies
article

End-Tidal Propofol Monitor Based on Deep Ultraviolet Fluorescence Spectroscopy Using Physics-Based Real-Time Correction and Deconvolution Models

Kenichi Masui, Takahiro Goto, Toshihide Hikida, Akio Shimono, Asao Mizoguchi
article en

Abstract

Since the 2007 report of a correlation between exhaled and plasma propofol using proton transfer reaction mass spectrometry, there has been a desire to develop clinically acceptable exhaled propofol monitors that are compact, simple, practical, and economical. Since the propofol concentration in the breathing circuit during anesthesia fluctuates significantly every 5−10 s, monitors used in anesthesia practice require high time-resolution and highly sensitive measurements to enable continuous monitoring. Additionally, the composition of the gas sampled from the breathing circuit changes frequently due to bidirectional flow in the circuit, drastic changes in matrix composition between inhaled and exhaled airs, especially water vapor, and the adsorption and desorption of propofol on the inner surfaces. A propofol concentration waveform is also required to confirm measurement validity in clinical practice, similar to a capnometer that continuously displays high-resolution waveforms. In this study, we developed a fluorescence gas instrument with a time resolution of 10 Hz using deep ultraviolet LED excitation. We implemented a real-time algorithm to precisely calculate and correct background signal and fluorescence quenching using physical models, while monitoring major matrix components with auxiliary sensors. The end-tidal propofol concentration of every ventilation period was then determined by applying a first-order lag model to propofol in the sidestream sampling. We successfully demonstrated breath-by-breath detection sensitivity down to 0.3 ppb for end-tidal propofol concentration with minimal calibration, indicating that a non-invasive end-tidal propofol monitor as a medical device is feasible.

Analytical Chemistry
Yokohama City University (JP)
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon