HSWL: A Deep Reinforcement Learning‐Driven Wear Leveling and Cache Management Strategy for Hybrid Flash SSDs

Data volumes continue to grow, and distributed storage systems assembled from large numbers of SSDs now form the backbone of modern data centers. Hybrid flash SSDs, which integrate high‐performance, long‐endurance SLC caches with cost‐effective, high‐density QLC main storage, achieve a compelling trade‐off among capacity, cost, and performance. However, the substantial discrepancy in P/E cycle endurance between the SLC cache and the QLC main storage region easily induces severe cross‐region wear imbalance, which shortens the overall lifespan of the SSD. This paper proposes HSWL, a cross‐region wear‐leveling and cache‐management strategy tailored for hybrid SLC/QLC flash SSDs. HSWL builds a Cache Decision Agent on the DQN framework. The agent observes the average wear, utilization, and wear‐distribution statistics of both regions and, at each decision point, chooses between evicting cold data to QLC and performing intra‐SLC garbage collection. The agent is paired with a numerically robust reward function and an LRU‐based victim‐selection policy. Experiments are conducted on the custom‐developed HybridSSDsim simulator using seven real‐world workload traces against three baselines: Circular‐log, a threshold heuristic, and a Samsung‐style RL‐based SLC cache manager. All results are averaged over five independent runs with different random seeds, and standard deviations are reported. Against the state‐of‐the‐art Circular‐log baseline, HSWL cuts the wear‐count variance σ 2 of the flash array by a geometric‐mean factor of 31× ± 1× and the endurance‐normalized total erase count by 5.3× ± 0.2×; it also lowers the average page write latency by 5.9× ± 0.2× and raises the SLC cache hit rate by 2.4× ± 0.1×. The extra RAM stays below 100 KB and inference takes 30–60 μs, which fits SSD‐controller firmware.

Authors

Institutions

Publication Details

Journal
Concurrency and Computation Practice and Experience
Published
2026-11-25
DOI
https://doi.org/10.1002/cpe.71038
Primary Topic
Advanced Data Storage Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

HSWL: A Deep Reinforcement Learning‐Driven Wear Leveling and Cache Management Strategy for Hybrid Flash SSDs

Genqing Bian, Qinlu He, Fan Zhang, Jiajing Wang et al.
Concurrency and Computation Practice and Experience
Advanced Data Storage Technologies
article

HSWL: A Deep Reinforcement Learning‐Driven Wear Leveling and Cache Management Strategy for Hybrid Flash SSDs

Genqing Bian, Qinlu He, Fan Zhang, Jiajing Wang, Weiqi Zhang
article en

Abstract

Data volumes continue to grow, and distributed storage systems assembled from large numbers of SSDs now form the backbone of modern data centers. Hybrid flash SSDs, which integrate high‐performance, long‐endurance SLC caches with cost‐effective, high‐density QLC main storage, achieve a compelling trade‐off among capacity, cost, and performance. However, the substantial discrepancy in P/E cycle endurance between the SLC cache and the QLC main storage region easily induces severe cross‐region wear imbalance, which shortens the overall lifespan of the SSD. This paper proposes HSWL, a cross‐region wear‐leveling and cache‐management strategy tailored for hybrid SLC/QLC flash SSDs. HSWL builds a Cache Decision Agent on the DQN framework. The agent observes the average wear, utilization, and wear‐distribution statistics of both regions and, at each decision point, chooses between evicting cold data to QLC and performing intra‐SLC garbage collection. The agent is paired with a numerically robust reward function and an LRU‐based victim‐selection policy. Experiments are conducted on the custom‐developed HybridSSDsim simulator using seven real‐world workload traces against three baselines: Circular‐log, a threshold heuristic, and a Samsung‐style RL‐based SLC cache manager. All results are averaged over five independent runs with different random seeds, and standard deviations are reported. Against the state‐of‐the‐art Circular‐log baseline, HSWL cuts the wear‐count variance σ 2 of the flash array by a geometric‐mean factor of 31× ± 1× and the endurance‐normalized total erase count by 5.3× ± 0.2×; it also lowers the average page write latency by 5.9× ± 0.2× and raises the SLC cache hit rate by 2.4× ± 0.1×. The extra RAM stays below 100 KB and inference takes 30–60 μs, which fits SSD‐controller firmware.

Concurrency and Computation Practice and ExperienceVol. 38(23)
Xi'an University of Architecture and Technology (CN)
Advanced Data Storage Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon