Cavitation inception delayed by structured surface roughness
Cavitation inception over structured rough surfaces is investigated experimentally in the diverging section of a Venturi. The diverging wall carries laser-etched checkerboards of square cavities with roughness aspect ratios $0.03 \leq k/d \leq 0.72$, tested at a Reynolds number of 95 160. Inception cavitation numbers were measured together with high-speed shadowgraphs of the near-wall flow, from which upstream-migrating nuclei were tracked and vapor-masked velocity fields were obtained by optical flow. Smooth walls recessed by the etched volume served as a control. The roughness delays inception, most strongly at intermediate $k/d$, where the inception cavitation number falls from 4.07 on the smooth wall to 3.33-3.46, whereas the recessed walls show no delay. The supply of nuclei is similar on all surfaces, so the delay does not come from a lack of nuclei. Instead, the roughness changes the near-wall flow. For $0.08 \leq k/d \leq 0.444$, a mean reverse-flow layer forms along the wall beneath a lifted shear layer, and vapor at inception appears further from the throat and away from the wall. At $k/d = 0.72$ the flow reverses only intermittently and the delay is smaller. On all surfaces except $k/d = 0.08$, the local cavitation number at inception varies linearly with the near-wall fluctuation energy, consistent with nuclei activated by pressure excursions about 6-8 times the r.m.s. fluctuation. The roughness thus delays inception not by limiting the nuclei, but by weakening the near-wall fluctuations that reach them.
Authors
- Olivier Coutier-Delgosha (ORCID: https://orcid.org/0000-0002-4881-7058)
- Naga Nitish Chamala
- Sanjay Vasanth Kethanur Balasubramaniam
Publication Details
- Journal
- arXiv
- Published
- 2026-11-24
- DOI
- https://doi.org/10.48550/arxiv.2611.31991
- Primary Topic
- Cavitation Phenomena in Pumps
- Type
- preprint