SNMICON 2026: Free Paper Abstracts (Oral and Poster Presentations)

Introduction: Metastatic pulmonary tumours remain challenging to treat, particularly when lesions are unsuitable for stereotactic body radiotherapy (SBRT) because of their number, size, or anatomical location.TARE through the bronchial or pulmonary arterial supply represents a potential treatment approach for such patients, enabling preferential delivery of therapeutic activity to tumour tissue while limiting radiation exposure to surrounding normal lung.However, the clinical translation of 90 Y-and 188 Re-based pulmonary radioembolisation requires further evaluation, particularly with regard to technical feasibility, treatmentrelated toxicity, radiation pneumonitis, and radiation exposure to critical organs at risk. Objectives: to evaluate the dosimetry and safety profile of 90Y-microspherese/188Re-lipiodol TARE in Metastatic Lung lesions.Material and Methods: Patients with measurable lung lesions of malignant origin with no other site of metastases on 18 F-FDG PET/CT were recruited for TARE.CT angiography to look for the predominant tumour artery supply was performed.Tumour volume was calculated by drawing a 3-D VOI around the PET/CT images, encompassing the metabolically active part of the tumour.The therapeutic activity was estimated using a single-compartment partition model.The decision about targeted tumour dose was adopted.Clinical and laboratory (investigational) toxicities were graded in accordance with CTCAE v5.0.Results: A total of 9 patients, mean age 48.6 years (6 male, 3 female), were recruited for this study.The median tumour size (maximum dimension) was 1.5 cm (1.5 to 2.3 cm).The median metabolic tumour volume was 1.9 cc (1-33 cc).The median administered activity ranged from 1.89 to 17.01 mCi, estimated using metabolic tumour volume and the partition method, with a median estimated tumour absorbed dose of 3200 Gy.Conclusion: This study explored the feasibility, safety, and dosimetry considerations of TARE for the management of metastatic lung tumours, an area with limited prior clinical exploration.No long-term adverse events were noted.

Publication Details

Journal
Indian Journal of Nuclear Medicine
Published
2026-11-25
DOI
https://doi.org/10.25259/ijnm_231_2026
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

SNMICON 2026: Free Paper Abstracts (Oral and Poster Presentations)

2 links
Indian Journal of Nuclear Medicine
Medical Imaging Techniques and Applications
article

SNMICON 2026: Free Paper Abstracts (Oral and Poster Presentations)

article en

Abstract

Introduction: Metastatic pulmonary tumours remain challenging to treat, particularly when lesions are unsuitable for stereotactic body radiotherapy (SBRT) because of their number, size, or anatomical location.TARE through the bronchial or pulmonary arterial supply represents a potential treatment approach for such patients, enabling preferential delivery of therapeutic activity to tumour tissue while limiting radiation exposure to surrounding normal lung.However, the clinical translation of 90 Y-and 188 Re-based pulmonary radioembolisation requires further evaluation, particularly with regard to technical feasibility, treatmentrelated toxicity, radiation pneumonitis, and radiation exposure to critical organs at risk. Objectives: to evaluate the dosimetry and safety profile of 90Y-microspherese/188Re-lipiodol TARE in Metastatic Lung lesions.Material and Methods: Patients with measurable lung lesions of malignant origin with no other site of metastases on 18 F-FDG PET/CT were recruited for TARE.CT angiography to look for the predominant tumour artery supply was performed.Tumour volume was calculated by drawing a 3-D VOI around the PET/CT images, encompassing the metabolically active part of the tumour.The therapeutic activity was estimated using a single-compartment partition model.The decision about targeted tumour dose was adopted.Clinical and laboratory (investigational) toxicities were graded in accordance with CTCAE v5.0.Results: A total of 9 patients, mean age 48.6 years (6 male, 3 female), were recruited for this study.The median tumour size (maximum dimension) was 1.5 cm (1.5 to 2.3 cm).The median metabolic tumour volume was 1.9 cc (1-33 cc).The median administered activity ranged from 1.89 to 17.01 mCi, estimated using metabolic tumour volume and the partition method, with a median estimated tumour absorbed dose of 3200 Gy.Conclusion: This study explored the feasibility, safety, and dosimetry considerations of TARE for the management of metastatic lung tumours, an area with limited prior clinical exploration.No long-term adverse events were noted.

Indian Journal of Nuclear MedicineVol. 41
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
SNMICON 2026: Free Paper Abstracts (Oral and Poster Presentations) · Indian Journal of Nuclear Medicine (2026) | TGRS Research Map | TGRS