Core Loss and No‐Load Current Investigation of Transformers With Different Core Materials Based on Frequency and Voltage

Transformers are essential power system equipment and continuously generate no‐load losses when energised. So, calculating the no‐load losses caused by the transformer must be performed at the design stage. No‐load current in transformers also determines the efficiency of the transformer. No‐load current is divided into iron current and magnetisation current. Depending on the induction of the transformer, the effect of the no‐load current components also changes. Therefore, this paper discusses the no‐load loss (P s) and reactive power (Q s) curves of the core in terms of induction and frequency dependence for different materials. P s and Q s have the same value at certain points, but especially as the material gets closer to the saturation region, the reactive power increases rapidly and becomes higher than P s. Analyses on a real transformer were performed in Ansys Maxwell and compared with test results. It was concluded that the no‐load current does not depend only on the core loss, and the effect of reactive power should be taken into consideration when making evaluations.

Authors

Institutions

Publication Details

Journal
High Voltage
Published
2026-11-24
DOI
https://doi.org/10.1049/hve2.70266
Primary Topic
Magnetic Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Core Loss and No‐Load Current Investigation of Transformers With Different Core Materials Based on Frequency and Voltage

Bora Alboyacı, Elif SAKALLIOĞLU, Yunus Berat Demirol
High Voltage
Magnetic Properties and Applications
article

Core Loss and No‐Load Current Investigation of Transformers With Different Core Materials Based on Frequency and Voltage

Bora Alboyacı, Elif SAKALLIOĞLU, Yunus Berat Demirol
article en

Abstract

Transformers are essential power system equipment and continuously generate no‐load losses when energised. So, calculating the no‐load losses caused by the transformer must be performed at the design stage. No‐load current in transformers also determines the efficiency of the transformer. No‐load current is divided into iron current and magnetisation current. Depending on the induction of the transformer, the effect of the no‐load current components also changes. Therefore, this paper discusses the no‐load loss (P s) and reactive power (Q s) curves of the core in terms of induction and frequency dependence for different materials. P s and Q s have the same value at certain points, but especially as the material gets closer to the saturation region, the reactive power increases rapidly and becomes higher than P s. Analyses on a real transformer were performed in Ansys Maxwell and compared with test results. It was concluded that the no‐load current does not depend only on the core loss, and the effect of reactive power should be taken into consideration when making evaluations.

High Voltage
Kocaeli Üniversitesi (TR)
Magnetic Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon