Dynamic Offset and Parametric Stop-Cylinder Protocol for Sleeveless Guided Implantology Across Monobloc and Two-Piece Systems

This technical note presents a dynamic offset and parametric stop-cylinder protocol for flapless, sleeveless computer-guided implant placement. The workflow is illustrated on two one-piece implant architectures—integrated-abutment implants (ROOTT C and CS series) and integrated-MUA implants (ROOTT M and P series)—and is designed to generalize to any monobloc or two-piece implant system utilizing a guided mounter, driver, or coaxial depth stop. When using a conventional coronal offset (such as 9 mm), the guide cylinder/sleeve can be short, increasing the risk of mechanical weakness or flex in the surgical guide. Shifting the offset coronally reinforces the guide cylinder engaging the drill/mounter and improves insertion axis stability. Correspondingly, the stop cylinder is dimensioned in inverse proportion to the offset (decreasing in height as the offset increases coronally, and vice versa), providing a physical depth stop that prevents over-insertion without removing the surgical guide. Published as a dated open-access defensive publication (prior art) to document the concept, geometric relationship, and chairside additive manufacturing workflow.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-25
DOI
https://doi.org/10.5281/zenodo.24531536
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Dynamic Offset and Parametric Stop-Cylinder Protocol for Sleeveless Guided Implantology Across Monobloc and Two-Piece Systems

Vincenzo Giorgino
Zenodo (CERN European Organization for Nuclear Research)
Dental Implant Techniques and Outcomes
article

Dynamic Offset and Parametric Stop-Cylinder Protocol for Sleeveless Guided Implantology Across Monobloc and Two-Piece Systems

Vincenzo Giorgino
article en

Abstract

This technical note presents a dynamic offset and parametric stop-cylinder protocol for flapless, sleeveless computer-guided implant placement. The workflow is illustrated on two one-piece implant architectures—integrated-abutment implants (ROOTT C and CS series) and integrated-MUA implants (ROOTT M and P series)—and is designed to generalize to any monobloc or two-piece implant system utilizing a guided mounter, driver, or coaxial depth stop. When using a conventional coronal offset (such as 9 mm), the guide cylinder/sleeve can be short, increasing the risk of mechanical weakness or flex in the surgical guide. Shifting the offset coronally reinforces the guide cylinder engaging the drill/mounter and improves insertion axis stability. Correspondingly, the stop cylinder is dimensioned in inverse proportion to the offset (decreasing in height as the offset increases coronally, and vice versa), providing a physical depth stop that prevents over-insertion without removing the surgical guide. Published as a dated open-access defensive publication (prior art) to document the concept, geometric relationship, and chairside additive manufacturing workflow.

Zenodo (CERN European Organization for Nuclear Research)
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon