A One-Year In Vivo Study of a Braided Pure Molybdenum Stent: Favorable Biocompatibility and the Critical Challenge of Vascular Biomechanics

Background: This study aims to evaluate a newly developed biodegradable stent made of pure Molybdenum (Mo) for treating intracranial aneurysms. Unlike traditional permanent metal stents that remain in the body indefinitely, this new device aims to provide temporary support during the healing process and then safely dissolve. Methods: A 30.48 µm braided Mo stent was developed, and its mechanical performance and degradation process were tested in vitro. The stent was then implanted into the arteries of Beagle dogs for a one-year observation period. The study compared these new stents against standard non-degradable stents to monitor safety, structural changes, and the degradation rate within a living organism. Results: The Mo stents demonstrated excellent biocompatibility, showing no signs of organ damage or neurotoxicity, and the material degraded at a rate suitable for aneurysm healing (4.88–5.12 µm/year). However, while the control stents held their shape, the Mo stents showed progressive structural deformation and recoil over time when implanted in the common carotid artery and subclavian artery of Beagle dogs. Conclusion: While this study confirms that Mo is a biocompatible material for stents, it highlights a major challenge in dynamic blood vessels. Future designs must focus on improving the stent's resistance to withstand the repetitive forces found in dynamic blood vessels before it can be considered for clinical use, and intracranial application still requires validation using aneurysm models in the future.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-11-25
DOI
https://doi.org/10.64898/2026.11.22.766907
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

A One-Year In Vivo Study of a Braided Pure Molybdenum Stent: Favorable Biocompatibility and the Critical Challenge of Vascular Biomechanics

Xinjian Yang, Fujunhui Zhang, Jinbiao Yao, Yisen Zhang et al.
bioRxiv (Cold Spring Harbor Laboratory)
Intracranial Aneurysms: Treatment and Complications
preprint

A One-Year In Vivo Study of a Braided Pure Molybdenum Stent: Favorable Biocompatibility and the Critical Challenge of Vascular Biomechanics

Xinjian Yang, Fujunhui Zhang, Jinbiao Yao, Yisen Zhang, Zhaoxu Zheng, Shuhan Wang, Yufeng Zheng, Youyuan Xiang, Weiming Liu, Tianyu Wei, Weiliang Jin, Xiangdong Liu, Ming Li, Bingqin Cai, Hui Huang
preprint en

Abstract

Background: This study aims to evaluate a newly developed biodegradable stent made of pure Molybdenum (Mo) for treating intracranial aneurysms. Unlike traditional permanent metal stents that remain in the body indefinitely, this new device aims to provide temporary support during the healing process and then safely dissolve. Methods: A 30.48 µm braided Mo stent was developed, and its mechanical performance and degradation process were tested in vitro. The stent was then implanted into the arteries of Beagle dogs for a one-year observation period. The study compared these new stents against standard non-degradable stents to monitor safety, structural changes, and the degradation rate within a living organism. Results: The Mo stents demonstrated excellent biocompatibility, showing no signs of organ damage or neurotoxicity, and the material degraded at a rate suitable for aneurysm healing (4.88–5.12 µm/year). However, while the control stents held their shape, the Mo stents showed progressive structural deformation and recoil over time when implanted in the common carotid artery and subclavian artery of Beagle dogs. Conclusion: While this study confirms that Mo is a biocompatible material for stents, it highlights a major challenge in dynamic blood vessels. Future designs must focus on improving the stent's resistance to withstand the repetitive forces found in dynamic blood vessels before it can be considered for clinical use, and intracranial application still requires validation using aneurysm models in the future.

bioRxiv (Cold Spring Harbor Laboratory)
Capital Medical University (CN), Peking University (CN), Beijing Tian Tan Hospital (CN), Xuan Wu Hospital of the Capital Medical University (CN), Beijing Institute of Neurosurgery (CN), Shenzhen Institute for Drug Control (CN)
Intracranial Aneurysms: Treatment and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon