A Novel Left‐Hand Tool Control System for Endoscopic Submucosal Dissection: Technical Description and Initial Clinical Experience (With Video)

In conventional endoscopic submucosal dissection (ESD), the operator's right hand alternates between stabilizing the endoscope shaft and manipulating the treatment device. We developed a left‐hand tool control system, assembled from a polytetrafluoroethylene tube, fixation tape, two plastic one‐touch clips serving as a movable device grip, and a sterile adapter cap, that relocates the accessory‐channel inlet into the left‐hand control field so that the knife is advanced and withdrawn with the left hand while the right hand maintains continuous scope control. Unlike existing left‐hand techniques, the grasping point lies only a short distance from the relocated inlet, which prevents the sheath from buckling during advancement. We report the initial experience in 41 consecutive ESD procedures (three esophageal, 13 gastric, and 25 colorectal) performed between June 2025 and April 2026. In every procedure, the operator maintained shaft torque and moved the knife simultaneously and without assistance. En bloc and R0 resection were each achieved in 39 procedures (95.1%), with no muscle injury or intraprocedural perforation. Within 3 weeks, one colorectal procedure was followed by delayed bleeding treated endoscopically and another by an unscheduled 3‐day prolongation of hospital stay. In an exploratory comparison adjusted for specimen area, fibrosis, age, and organ, ESD time was not shorter than in conventional procedures by the same operator during the preceding 2 years (time ratio 1.23, 95% confidence interval 1.00–1.52). The system was feasible in this single‐operator series; its effect on procedural efficiency and its safety require prospective evaluation.

Authors

Institutions

Publication Details

Journal
DEN Open
Published
2026-11-25
DOI
https://doi.org/10.1002/deo2.70472
Primary Topic
Gastric Cancer Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Novel Left‐Hand Tool Control System for Endoscopic Submucosal Dissection: Technical Description and Initial Clinical Experience (With Video)

Hidetaka Ohta, Atsushi Miwa
DEN Open
Gastric Cancer Management and Outcomes
article

A Novel Left‐Hand Tool Control System for Endoscopic Submucosal Dissection: Technical Description and Initial Clinical Experience (With Video)

Hidetaka Ohta, Atsushi Miwa
article en

Abstract

In conventional endoscopic submucosal dissection (ESD), the operator's right hand alternates between stabilizing the endoscope shaft and manipulating the treatment device. We developed a left‐hand tool control system, assembled from a polytetrafluoroethylene tube, fixation tape, two plastic one‐touch clips serving as a movable device grip, and a sterile adapter cap, that relocates the accessory‐channel inlet into the left‐hand control field so that the knife is advanced and withdrawn with the left hand while the right hand maintains continuous scope control. Unlike existing left‐hand techniques, the grasping point lies only a short distance from the relocated inlet, which prevents the sheath from buckling during advancement. We report the initial experience in 41 consecutive ESD procedures (three esophageal, 13 gastric, and 25 colorectal) performed between June 2025 and April 2026. In every procedure, the operator maintained shaft torque and moved the knife simultaneously and without assistance. En bloc and R0 resection were each achieved in 39 procedures (95.1%), with no muscle injury or intraprocedural perforation. Within 3 weeks, one colorectal procedure was followed by delayed bleeding treated endoscopically and another by an unscheduled 3‐day prolongation of hospital stay. In an exploratory comparison adjusted for specimen area, fibrosis, age, and organ, ESD time was not shorter than in conventional procedures by the same operator during the preceding 2 years (time ratio 1.23, 95% confidence interval 1.00–1.52). The system was feasible in this single‐operator series; its effect on procedural efficiency and its safety require prospective evaluation.

DEN OpenVol. 7(1)
Kurosawa Hospital (JP)
Gastric Cancer Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon