Utilizing AI Decision Support Tools in Burn Resuscitation: Comparing A Large Language Model to a Computerized Decision Support Tool

Crystalloid resuscitation is central to severe burn care. Traditional approaches rely on calculated formulae, monitoring, and endpoint guided titration. Computerized Clinical Decision Support (CDS) tools automate this process and improve goal-directed outcomes, but use remains limited due to accessibility. Large Language Models (LLMs) offer an unevaluated alternative. This study compared crystalloid estimates between a commonly used LLM and CDS system. A retrospective one-year two phase analysis was conducted for adult patients treated at an ABA-verified burn center who received individualized CDS-guided fluid resuscitation during the first 24 hours after injury. An LLM was queried using standardized prompts based on identical clinical inputs used by the CDS tool, including age, TBSA, weight, formulae, urine output, and confounders. Bland-Altman analysis assessed fluid volume predictions between the LLM and CDS system. This study included eighteen patients with a mean ± SD TBSA burn of 41.7% ± 20.2%, contributing 387 recommendations in Phase 1 and 380 in Phase 2. Mean LLM and CDS system rates through 24 hours post-burn were not statistically significant different (462 ± 318 mL/hr vs 450 ± 288 mL/hr; p=0.57). Correlation between the two systems was strong (r=0.93; 95% CI, 0.91-0.94, p<0.0001) with a mean difference of 12.3 mL/hr (95% limits of agreement, -222 to 246 mL/hr). Following prompt refinement, Phase 2 correlation remained strong (r=0.94; 95% CI, 0.93-0.95, p<0.0001) with a mean difference of -23.4 mL/hr and limits of agreement ranging from -178.3 to 131.5 mL/hr. LLMs can generate sequential fluid-rate recommendations during simulated burn resuscitation, but variability in fluid rates highlight the need for further refinement and clinical validation.

Authors

Institutions

Publication Details

Journal
Journal of Burn Care & Research
Published
2026-11-25
DOI
https://doi.org/10.1093/jbcr/irag195
Primary Topic
Burn Injury Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Utilizing AI Decision Support Tools in Burn Resuscitation: Comparing A Large Language Model to a Computerized Decision Support Tool

Jeffrey W. Shupp, Bonnie C Carney, Shawn Tejiram, Atharva Bendre et al.
Journal of Burn Care & Research
Burn Injury Management and Outcomes
article

Utilizing AI Decision Support Tools in Burn Resuscitation: Comparing A Large Language Model to a Computerized Decision Support Tool

Jeffrey W. Shupp, Bonnie C Carney, Shawn Tejiram, Atharva Bendre, Lauren T. Moffatt, Tamer Rajai Hage, Alina Watson, Tuan Le
article en

Abstract

Crystalloid resuscitation is central to severe burn care. Traditional approaches rely on calculated formulae, monitoring, and endpoint guided titration. Computerized Clinical Decision Support (CDS) tools automate this process and improve goal-directed outcomes, but use remains limited due to accessibility. Large Language Models (LLMs) offer an unevaluated alternative. This study compared crystalloid estimates between a commonly used LLM and CDS system. A retrospective one-year two phase analysis was conducted for adult patients treated at an ABA-verified burn center who received individualized CDS-guided fluid resuscitation during the first 24 hours after injury. An LLM was queried using standardized prompts based on identical clinical inputs used by the CDS tool, including age, TBSA, weight, formulae, urine output, and confounders. Bland-Altman analysis assessed fluid volume predictions between the LLM and CDS system. This study included eighteen patients with a mean ± SD TBSA burn of 41.7% ± 20.2%, contributing 387 recommendations in Phase 1 and 380 in Phase 2. Mean LLM and CDS system rates through 24 hours post-burn were not statistically significant different (462 ± 318 mL/hr vs 450 ± 288 mL/hr; p=0.57). Correlation between the two systems was strong (r=0.93; 95% CI, 0.91-0.94, p<0.0001) with a mean difference of 12.3 mL/hr (95% limits of agreement, -222 to 246 mL/hr). Following prompt refinement, Phase 2 correlation remained strong (r=0.94; 95% CI, 0.93-0.95, p<0.0001) with a mean difference of -23.4 mL/hr and limits of agreement ranging from -178.3 to 131.5 mL/hr. LLMs can generate sequential fluid-rate recommendations during simulated burn resuscitation, but variability in fluid rates highlight the need for further refinement and clinical validation.

Journal of Burn Care & Research
MedStar Washington Hospital Center (US), Georgetown University (US), Virginia Commonwealth University (US), MedStar Health Research Institute (US), University of Virginia (US)
Burn Injury Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon