Possibility of Using a Photovoltaic Arrow Chart for Detecting the Cause of Degradation of Solar Cells from I-V Measurement
An experimental study was conducted to identify if there are specific responses of photovoltaic parameters to different degradation treatments, including broken contact fingers, surface scratching, heat treatment and partial shading. The experimental data obtained from this investigation show that the degradation caused by broken contact fingers, surface scratching, and partial shading exhibited complex, but characteristic, changes in the photovoltaic parameters. Further investigation along this line of research led to the development of a photovoltaic arrow chart based on four photovoltaic ratios proposed in this work. The results show the possibility of using this arrow chart to identify the cause of degradation using only the I-V measurement, providing a promising, simple approach to study the stability and degradation of solar cells. In addition, the photovoltaic arrow chart can provide insights into the underlying losses in the photovoltaic processes due to these degradations.
Authors
- Gao Min (ORCID: https://orcid.org/0000-0001-9591-5825)
- Abdulaziz Alghlaigah (ORCID: https://orcid.org/0000-0002-8436-0307)
Institutions
- King Faisal University (SA)
- Cardiff University (GB)
Publication Details
- Journal
- Photovoltaics
- Published
- 2026-11-25
- DOI
- https://doi.org/10.3390/photovoltaics1010004
- Primary Topic
- Silicon and Solar Cell Technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00