Optimal configuration of competitive merging flows

Competitive merging flows are a complex fluid mechanics problem, for which the optimal configuration remains elusive. In the present work, we identified energetically favourable merging inflows configurations by using a topology-optimisation framework. For this purpose, an idealised aorto-coronary bypass graft is employed as a model problem in which the balance between native coronary and graft inflows varies with stenosis severity. Counterintuitively, the ratio between the coronary and bypass flow rates, phi ϕ $\phi$, is negatively proportional to the optimal attachment angle of the bypass to the receiving vessel. The corresponding haemodynamics clearly shows a transition from the condition of comparable contributions from the two vessels (phi tilde script upper O left parenthesis 1 right parenthesis ϕ ∼ O (1) $\phi \sim \mathcal{O}(1)$) to a dominant bypass condition (phi tilde script upper O left parenthesis 10 Superscript negative 2 Baseline right parenthesis ϕ ∼ O (10 − 2) $\phi \sim \mathcal{O}(10^{-2})$). In the first case, strong shear layers, flow non-uniformity, and appreciable localised dissipation across the stenosis characterise the blood dynamics in the coronary artery. In contrast, in the second scenario, the optimised configurations shift towards more coherent flow coupling with reduced localised losses, prevalently occurring at the anastomosis junction. Therefore, the optimal configurations arise not from a uniform reduction of viscous dissipation, but from its redistribution within the domain: as stenosis severity increases, losses are progressively shifted from the constricted coronary segment to the anastomosis, where competing inflows irreversibly redistribute momentum. These findings demonstrate that the optimal merging flows configuration is not universal, but emerges from the balance between competing momentum fluxes and the associated partition of energy losses between localised and distributed viscous dissipation.

Authors

Institutions

Publication Details

Journal
Journal of Fluid Mechanics
Published
2026-11-25
DOI
https://doi.org/10.1017/jfm.2026.12311
Primary Topic
Topology Optimization in Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Optimal configuration of competitive merging flows

G. Boscolo, Paolo Peruzzo
Journal of Fluid Mechanics
Topology Optimization in Engineering
article

Optimal configuration of competitive merging flows

G. Boscolo, Paolo Peruzzo
article en

Abstract

Competitive merging flows are a complex fluid mechanics problem, for which the optimal configuration remains elusive. In the present work, we identified energetically favourable merging inflows configurations by using a topology-optimisation framework. For this purpose, an idealised aorto-coronary bypass graft is employed as a model problem in which the balance between native coronary and graft inflows varies with stenosis severity. Counterintuitively, the ratio between the coronary and bypass flow rates, phi ϕ $\phi$, is negatively proportional to the optimal attachment angle of the bypass to the receiving vessel. The corresponding haemodynamics clearly shows a transition from the condition of comparable contributions from the two vessels (phi tilde script upper O left parenthesis 1 right parenthesis ϕ ∼ O (1) $\phi \sim \mathcal{O}(1)$) to a dominant bypass condition (phi tilde script upper O left parenthesis 10 Superscript negative 2 Baseline right parenthesis ϕ ∼ O (10 − 2) $\phi \sim \mathcal{O}(10^{-2})$). In the first case, strong shear layers, flow non-uniformity, and appreciable localised dissipation across the stenosis characterise the blood dynamics in the coronary artery. In contrast, in the second scenario, the optimised configurations shift towards more coherent flow coupling with reduced localised losses, prevalently occurring at the anastomosis junction. Therefore, the optimal configurations arise not from a uniform reduction of viscous dissipation, but from its redistribution within the domain: as stenosis severity increases, losses are progressively shifted from the constricted coronary segment to the anastomosis, where competing inflows irreversibly redistribute momentum. These findings demonstrate that the optimal merging flows configuration is not universal, but emerges from the balance between competing momentum fluxes and the associated partition of energy losses between localised and distributed viscous dissipation.

Journal of Fluid MechanicsVol. 1047
University of Padua (IT), Universitat Politècnica de Catalunya (ES)
Topology Optimization in Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon