Risk-Constrained Wastewater Control under Missing Sensor Measurements: Analysis of an Original Hourly Dataset with Dhaka-Relevant Ecological Conditions
Intermittent instrumentation failure is a persistent obstacle to dependable wastewater control, and its consequences are most severe in catchments where receiving waters are already ecologically degraded. This study analyzes an original hourly operational dataset spanning 90 consecutive days to examine how incomplete dissolved oxygen measurements influence treatment performance, effluent release decisions, and receiving-water oxygen condition under circumstances comparable to those of Dhaka, Bangladesh. The dataset comprises 2,160 hourly records for each of three control strategies, giving 6,480 strategy-level records in total, and it carries a full set of process, effluent, and receiving-water variables. Dissolved oxygen measurements were absent or stale during 20.83 percent of time steps. Three strategies were assessed on the identical hourly record: fixed feedback control at a constant aeration setting of 0.62, imputation-based control that acted on the most recent dissolved oxygen estimate, and risk-constrained control that adjusted aeration according to both the estimated concentration and its accumulated uncertainty. Under risk-constrained control, the release gate withheld wastewater whenever estimation uncertainty exceeded 0.55 mg/L or estimated dissolved oxygen fell below 1.75 mg/L. Mean effluent biochemical oxygen demand declined from 25.28 mg/L under fixed feedback control to 22.43 mg/L under risk-constrained control, a reduction of approximately 11.3 percent, while the share of time steps exceeding the 20 mg/L benchmark fell from 84.82 to 69.82 percent. Mean receiving-water dissolved oxygen rose from 4.84 to 5.02 mg/L, and the proportion of hours with river dissolved oxygen below the 4 mg/L screening threshold declined from 13.38 to 7.13 percent, a relative reduction of approximately 46.7 percent. These ecological gains carried a measurable operational cost, because wastewater was withheld from release during 11.62 percent of time steps, equivalent to 251 of the 2,160 hours. The evidence indicates that treating outage duration as an explicit uncertainty term, rather than substituting a single best estimate, offers a defensible basis for coupling treatment control with release safety in data-scarce settings.
Authors
- Nafisa Mosaddek (ORCID: https://orcid.org/0000-0002-5003-0772)
- Layama Maisha
Institutions
- Bangladesh Army University of Science and Technology (BD)
- Bangladesh University of Professionals (BD)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-25
- DOI
- https://doi.org/10.21203/rs.3.rs-11481740/v1
- Primary Topic
- Water Quality Monitoring and Analysis
- Type
- preprint