Implantation site influences tissue response to vaginal meshes in a material dependent manner

Polypropylene (PP) meshes are associated with significant complications when implanted transvaginally for the treatment of stress urinary incontinence (SUI) and pelvic organ prolapse (POP). Efforts to circumvent this include developing more biocompatible synthetic materials and improving the pre-clinical development pathways. In this study, we compared the tissue response to novel vaginal meshes in a more traditional abdominal wall implantation and a more representative vaginal implantation model. Two novel electrospun poly-urethane (PU) and poly-lactic acid (PLA) materials were implanted in the vesico-vaginal space (VVs) and abdominal wall of female rabbits. Estradiol (E 2 )-loaded PU (PU-E 2 ) was also implanted to compare it against unloaded PU mesh. A polypropylene (PP) mesh was used as a control. After three months, assessment of the implantation site revealed distinct reactions to the implants between the abdominal wall and vesicovaginal implantation sites. Extrusion and contraction of the meshes were only seen for PP and PLA in the vaginal implantation sites. Histologic examination revealed a mild inflammatory response to both PU and PP meshes in both implantation sites; while a strong inflammatory response was observed for PLA meshes. The capsule formation was similar between all groups and implantation sites, except for a thicker capsule for PP meshes implanted vaginally. Additionally, estradiol loaded PU meshes increased the cell infiltration and blood vessel formation compared to unloaded PU, particularly after vaginal implantation. The tissue response to mesh materials differed between abdominal and vaginal implantation in a material-dependent manner (significant for PLA and PU-E 2 but not PP or PU). Implant-related complications were observed only following vaginal implantation. These findings suggest that the implantation site may influence the preclinical evaluation of biomaterials intended for vaginal application. Further studies are warranted to determine whether anatomically relevant implantation models provide additional predictive value for the preclinical assessment of vaginal biomaterials.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-25
DOI
https://doi.org/10.1038/s41598-026-79231-5
Primary Topic
Pelvic floor disorders treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Implantation site influences tissue response to vaginal meshes in a material dependent manner

Özlem Bozdemir, Vanessa L. Hearnden, Kezban Ulubayram, Şükrü Öztürk et al.
Scientific Reports
Pelvic floor disorders treatments
article

Implantation site influences tissue response to vaginal meshes in a material dependent manner

Özlem Bozdemir, Vanessa L. Hearnden, Kezban Ulubayram, Şükrü Öztürk, Sheila MacNeil, Christopher Reginald Chapple, Naşide Mangır, Naciye Dilara Zeybek, Sabiniano Roman Regueros
article en

Abstract

Polypropylene (PP) meshes are associated with significant complications when implanted transvaginally for the treatment of stress urinary incontinence (SUI) and pelvic organ prolapse (POP). Efforts to circumvent this include developing more biocompatible synthetic materials and improving the pre-clinical development pathways. In this study, we compared the tissue response to novel vaginal meshes in a more traditional abdominal wall implantation and a more representative vaginal implantation model. Two novel electrospun poly-urethane (PU) and poly-lactic acid (PLA) materials were implanted in the vesico-vaginal space (VVs) and abdominal wall of female rabbits. Estradiol (E 2 )-loaded PU (PU-E 2 ) was also implanted to compare it against unloaded PU mesh. A polypropylene (PP) mesh was used as a control. After three months, assessment of the implantation site revealed distinct reactions to the implants between the abdominal wall and vesicovaginal implantation sites. Extrusion and contraction of the meshes were only seen for PP and PLA in the vaginal implantation sites. Histologic examination revealed a mild inflammatory response to both PU and PP meshes in both implantation sites; while a strong inflammatory response was observed for PLA meshes. The capsule formation was similar between all groups and implantation sites, except for a thicker capsule for PP meshes implanted vaginally. Additionally, estradiol loaded PU meshes increased the cell infiltration and blood vessel formation compared to unloaded PU, particularly after vaginal implantation. The tissue response to mesh materials differed between abdominal and vaginal implantation in a material-dependent manner (significant for PLA and PU-E 2 but not PP or PU). Implant-related complications were observed only following vaginal implantation. These findings suggest that the implantation site may influence the preclinical evaluation of biomaterials intended for vaginal application. Further studies are warranted to determine whether anatomically relevant implantation models provide additional predictive value for the preclinical assessment of vaginal biomaterials.

Scientific Reports
Sheffield Teaching Hospitals NHS Foundation Trust (GB), Hacettepe University (TR), University of Sheffield (GB)
Pelvic floor disorders treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon