An Adaptive Hybrid Deep Learning Framework for Known and Zero- Day Cyberattack Detection in Next-Generation Smart Grids

Next-generation smart grids are exposed to false data injection, denial-of-service, replay, malware and previously unseen (zero-day) cyberattacks, yet most deep-learning intrusion detectors are trained on a closed set of known attacks and misclassify novel attacks silently. This paper proposes an adaptive physics-guided dual-branch Transformer–autoencoder intrusion detection (PG-ADTA-ID) framework. A physics-guided spatiotemporal Transformer with a breaker-aware graph embedding and Kirchhoff, Ohm and metering residuals classifies known attacks. A self-supervised denoising autoencoder models the known world through a reconstruction-error signature computed on channels that do not scale with the operating point. A physics-consistent open-set fusion turns classification uncertainty, reconstruction surprise and physics-consistency surprise into a calibrated novelty-risk score with a three-way decision, and physics-gated continual learning adapts the threshold and the models under concept drift. Formal results establish the operating-point invariance of the physics residuals, the visibility of power-flow-consistent injections, false-alarm control and the bounded influence of poisoning on adaptation. On a cyber-physical co-simulation of the IEEE 14-bus system with four known and five withheld attack families, PG-ADTA-ID achieved 99.30% accuracy and a 98.74% macro-F1-score on known attacks, detected 90.7% of the zero-day attack episodes and flagged 54.4% of the zero-day windows as unknown at a false-positive rate of 1.69%. Its area under the receiver operating characteristic curve for zero-day versus known traffic was 0.934, against at most 0.804 for eleven baselines. Under concept drift, continual learning reduced the false-positive rate from 100% to 11.0%, and a complete decision took 7.23 ms per window on a two-core processor.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-25
DOI
https://doi.org/10.21203/rs.3.rs-11514914/v1
Primary Topic
Smart Grid Security and Resilience
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

An Adaptive Hybrid Deep Learning Framework for Known and Zero- Day Cyberattack Detection in Next-Generation Smart Grids

N Sharmila, S Mallikarjunaswamy, C Chandana, D Prakyath et al.
Research Square
Smart Grid Security and Resilience
preprint

An Adaptive Hybrid Deep Learning Framework for Known and Zero- Day Cyberattack Detection in Next-Generation Smart Grids

N Sharmila, S Mallikarjunaswamy, C Chandana, D Prakyath, H S Chethana
preprint en

Abstract

Next-generation smart grids are exposed to false data injection, denial-of-service, replay, malware and previously unseen (zero-day) cyberattacks, yet most deep-learning intrusion detectors are trained on a closed set of known attacks and misclassify novel attacks silently. This paper proposes an adaptive physics-guided dual-branch Transformer–autoencoder intrusion detection (PG-ADTA-ID) framework. A physics-guided spatiotemporal Transformer with a breaker-aware graph embedding and Kirchhoff, Ohm and metering residuals classifies known attacks. A self-supervised denoising autoencoder models the known world through a reconstruction-error signature computed on channels that do not scale with the operating point. A physics-consistent open-set fusion turns classification uncertainty, reconstruction surprise and physics-consistency surprise into a calibrated novelty-risk score with a three-way decision, and physics-gated continual learning adapts the threshold and the models under concept drift. Formal results establish the operating-point invariance of the physics residuals, the visibility of power-flow-consistent injections, false-alarm control and the bounded influence of poisoning on adaptation. On a cyber-physical co-simulation of the IEEE 14-bus system with four known and five withheld attack families, PG-ADTA-ID achieved 99.30% accuracy and a 98.74% macro-F1-score on known attacks, detected 90.7% of the zero-day attack episodes and flagged 54.4% of the zero-day windows as unknown at a false-positive rate of 1.69%. Its area under the receiver operating characteristic curve for zero-day versus known traffic was 0.934, against at most 0.804 for eleven baselines. Under concept drift, continual learning reduced the false-positive rate from 100% to 11.0%, and a complete decision took 7.23 ms per window on a two-core processor.

Research Square
JSS Academy of Higher Education and Research (IN), JSS Science and Technology University (IN)
Smart Grid Security and Resilience
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon