Experimental Study on the Suppression of Lithium Iron Phosphate Battery Fires Using Thermoresponsive Hydrogel

This study links the formulation of a thermoresponsive hydrogel to the effect of dilution on three stages of lithium iron phosphate (LFP) battery fire suppression: flame extinction, cooling during spraying, and temperature rebound after spraying. We screened a hydrogel containing methylcellulose (MC), sodium alginate (SA), magnesium chloride (MgCl2), ammonium polyphosphate (APP), and glycerol by measuring its viscosity, thermal gelation, flame suppression performance, and mass loss during heating. We then compared five dilutions of the selected stock formulation with pure water in fire tests on 20 Ah LFP cells. The selected stock formulation comprised 0.8% MC, 0.8% SA, 0.7% MgCl2, 3% APP, and 4% glycerol. The 7% dilution extinguished visible flames in 11 s, compared with 23 s for pure water. Over the 75 s discharge period, the five-point mean temperature fell by 269.0 °C with the 7% dilution, a 74.45% greater reduction than with pure water. The spatial maximum fell by 598 °C over the same interval, giving an average cooling rate of 7.973 °C·s−1. The 9% dilution produced a larger drop in mean temperature (279.6 °C), whereas the 7% dilution showed lower temperature rebound rates after spraying ceased. The post-extinguishment rebound rates of the average and maximum temperatures were 0.0041 and 0.0448 °C·s−1, respectively. The specific enthalpy reached 2532.34 J·g−1, with an endothermic interval of 23.4~178.3 °C. Thermally induced gelation, evaporative heat absorption, stable surface coverage, prolonged action through water retention, and gas- and condensed-phase flame retardancy jointly enabled rapid extinguishment, sustained cooling, and reduced short-term temperature rise and reignition risks. These findings provide a basis for developing aqueous extinguishing materials for LFP battery fires.

Authors

Institutions

Publication Details

Journal
Fire
Published
2026-11-25
DOI
https://doi.org/10.3390/fire9120529
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Experimental Study on the Suppression of Lithium Iron Phosphate Battery Fires Using Thermoresponsive Hydrogel

Shunbing Zhu, Yang Liu, Menglan Zhang, Qingyu Chen et al.
Fire
Fire dynamics and safety research
article

Experimental Study on the Suppression of Lithium Iron Phosphate Battery Fires Using Thermoresponsive Hydrogel

Shunbing Zhu, Yang Liu, Menglan Zhang, Qingyu Chen, Yu Lu
article en

Abstract

This study links the formulation of a thermoresponsive hydrogel to the effect of dilution on three stages of lithium iron phosphate (LFP) battery fire suppression: flame extinction, cooling during spraying, and temperature rebound after spraying. We screened a hydrogel containing methylcellulose (MC), sodium alginate (SA), magnesium chloride (MgCl2), ammonium polyphosphate (APP), and glycerol by measuring its viscosity, thermal gelation, flame suppression performance, and mass loss during heating. We then compared five dilutions of the selected stock formulation with pure water in fire tests on 20 Ah LFP cells. The selected stock formulation comprised 0.8% MC, 0.8% SA, 0.7% MgCl2, 3% APP, and 4% glycerol. The 7% dilution extinguished visible flames in 11 s, compared with 23 s for pure water. Over the 75 s discharge period, the five-point mean temperature fell by 269.0 °C with the 7% dilution, a 74.45% greater reduction than with pure water. The spatial maximum fell by 598 °C over the same interval, giving an average cooling rate of 7.973 °C·s−1. The 9% dilution produced a larger drop in mean temperature (279.6 °C), whereas the 7% dilution showed lower temperature rebound rates after spraying ceased. The post-extinguishment rebound rates of the average and maximum temperatures were 0.0041 and 0.0448 °C·s−1, respectively. The specific enthalpy reached 2532.34 J·g−1, with an endothermic interval of 23.4~178.3 °C. Thermally induced gelation, evaporative heat absorption, stable surface coverage, prolonged action through water retention, and gas- and condensed-phase flame retardancy jointly enabled rapid extinguishment, sustained cooling, and reduced short-term temperature rise and reignition risks. These findings provide a basis for developing aqueous extinguishing materials for LFP battery fires.

FireVol. 9(12)
Nanjing Tech University (CN)
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon