Biological characterization and bilateral intraocular concordance of near real surgical specimens: a human ex vivo platform for controlled intraocular research

Background Experimental models of the human eye underpin vitreoretinal research and surgical training, and their value depends on how faithfully they preserve native tissue structure and biology. Existing human ex vivo models rely on isolated tissue segments or enucleated globes that do not preserve operative anatomy. Near Real Surgical Specimens (NRSS) are intact human donor head preparations in which both globes are retained in situ within the orbit, with native periocular anatomy and tissue relationships intact, prepared without aldehyde fixation. Prior work established the mechanical reproducibility of the platform. This study presents its first biological characterization and evaluates whether intraocular measurements are concordant between paired eyes. Methods Six NRSS specimens (12 eyes) from de-identified, research-consented donors were studied. Retinal explants from two specimens (four retinas) were mechanically dissociated, and membrane-intact viable cells were counted by trypan blue exclusion on a hemocytometer in two technical replicates per retina. Vitreous humor was assayed for hydrogen peroxide (H2O2) by fluorometric assay and for interleukin-6 (IL-6), tumor necrosis factor-alpha (TNF-α), and interleukin-1 beta (IL-1β) by sandwich ELISA. Bilateral agreement was assessed by intraclass correlation (ICC(A,1)), Bland-Altman analysis, and Pearson correlation, and intra-specimen and inter-specimen coefficients of variation (CV) were compared by Welch t-test. Results Mechanical dissociation yielded 15.8 to 24.3 ×10 6 membrane-intact viable cells per retina across four retinas. H2O2 was measurable in all 12 eyes (mean: 11.51 ± 2.67 μM; ICC(A,1) = 0.875; r = 0.943, p = 0.005). IL-6 was detectable in all 12 eyes (geometric mean: 34.0 pg/mL; ICC(A,1) = 0.917; r = 0.940, p = 0.005). Intra-specimen CV was significantly lower than inter-specimen CV for H2O2 (8.4 ± 5.3% vs. 19.2 ± 10.5%; p = 0.006) and IL-6 (31.9 ± 14.7% vs. 76.0 ± 29.0%; p = 0.0002). TNF-α was detectable in 2 of 12 eyes; IL-1β was undetectable. Conclusions NRSS specimens yielded viable retinal cells and measurable, bilaterally concordant vitreous H2O2 and IL-6. These findings provide the first biological characterization of the platform and support a paired-eye, contralateral-control design in which the fellow eye serves as a within-donor control. Extension to pharmacological and disease-modeling applications will follow further validation.

Authors

Institutions

Publication Details

Journal
Frontiers in Ophthalmology
Published
2026-11-25
DOI
https://doi.org/10.3389/fopht.2026.1917720
Primary Topic
Retinal and Macular Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Biological characterization and bilateral intraocular concordance of near real surgical specimens: a human ex vivo platform for controlled intraocular research

Vinit B. Mahajan, Dimitrios C. Arhontoulis, Yoreh Barak, Mahita Kadmiel et al.
Frontiers in Ophthalmology
Retinal and Macular Surgery
article

Biological characterization and bilateral intraocular concordance of near real surgical specimens: a human ex vivo platform for controlled intraocular research

Vinit B. Mahajan, Dimitrios C. Arhontoulis, Yoreh Barak, Mahita Kadmiel, Ryan W. Barrs, David R.P. Almeida, Evan A. Ehrensing
article en

Abstract

Background Experimental models of the human eye underpin vitreoretinal research and surgical training, and their value depends on how faithfully they preserve native tissue structure and biology. Existing human ex vivo models rely on isolated tissue segments or enucleated globes that do not preserve operative anatomy. Near Real Surgical Specimens (NRSS) are intact human donor head preparations in which both globes are retained in situ within the orbit, with native periocular anatomy and tissue relationships intact, prepared without aldehyde fixation. Prior work established the mechanical reproducibility of the platform. This study presents its first biological characterization and evaluates whether intraocular measurements are concordant between paired eyes. Methods Six NRSS specimens (12 eyes) from de-identified, research-consented donors were studied. Retinal explants from two specimens (four retinas) were mechanically dissociated, and membrane-intact viable cells were counted by trypan blue exclusion on a hemocytometer in two technical replicates per retina. Vitreous humor was assayed for hydrogen peroxide (H2O2) by fluorometric assay and for interleukin-6 (IL-6), tumor necrosis factor-alpha (TNF-α), and interleukin-1 beta (IL-1β) by sandwich ELISA. Bilateral agreement was assessed by intraclass correlation (ICC(A,1)), Bland-Altman analysis, and Pearson correlation, and intra-specimen and inter-specimen coefficients of variation (CV) were compared by Welch t-test. Results Mechanical dissociation yielded 15.8 to 24.3 ×10 6 membrane-intact viable cells per retina across four retinas. H2O2 was measurable in all 12 eyes (mean: 11.51 ± 2.67 μM; ICC(A,1) = 0.875; r = 0.943, p = 0.005). IL-6 was detectable in all 12 eyes (geometric mean: 34.0 pg/mL; ICC(A,1) = 0.917; r = 0.940, p = 0.005). Intra-specimen CV was significantly lower than inter-specimen CV for H2O2 (8.4 ± 5.3% vs. 19.2 ± 10.5%; p = 0.006) and IL-6 (31.9 ± 14.7% vs. 76.0 ± 29.0%; p = 0.0002). TNF-α was detectable in 2 of 12 eyes; IL-1β was undetectable. Conclusions NRSS specimens yielded viable retinal cells and measurable, bilaterally concordant vitreous H2O2 and IL-6. These findings provide the first biological characterization of the platform and support a paired-eye, contralateral-control design in which the fellow eye serves as a within-donor control. Extension to pharmacological and disease-modeling applications will follow further validation.

Frontiers in OphthalmologyVol. 6
Allegheny College (US), University of New Orleans (US), Rambam Health Care Campus (IL), University Medical Center New Orleans (US), Smith-Kettlewell Eye Research Institute (US), Louisiana State University Health Sciences Center New Orleans (US)
Retinal and Macular Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon