Late-fusion radiomics with multi-sequence MRI distinguishes benign from malignant ovarian tumors: a two-center study
Preoperative differentiation of benign from malignant ovarian tumors guides surgical planning, but single-sequence radiomics models leave complementary MRI information unused, and whether fusion should occur before or after modelling is unresolved. We studied 268 lesions from 231 patients at two centers; borderline tumors were grouped with malignant tumors, so “malignant” denotes the combined malignant/borderline endpoint (45 of 225 lesions in the training cohort and 9 of 43 in the external cohort). Center 1 (225 lesions) was the training cohort, analysed with patient-level five-fold GroupKFold cross-validation, and Center 2 (43 lesions) the external cohort, evaluated once. For four sequences (T1WI, T2WI fs, DWI, CE-T1WI), 1,197 PyRadiomics features per sequence were selected within each training fold, and the algorithm with the highest mean cross-validated AUC was carried forward. Early fusion concatenated and re-selected the features for logistic regression; late fusion averaged the four models with equal log-odds weights. Thresholds fixed on out-of-fold training predictions were applied unchanged externally. At those thresholds late fusion had the highest accuracy (0.884), specificity (0.912) and positive predictive value (0.700) and the lowest Brier score (0.143; 0.130 after Platt scaling) of the six models, classifying 3 of 34 benign lesions as malignant, against 16 for the best single sequence and 19 for T2WI fs, at the cost of one more missed malignant lesion (2 versus 1 of 9). Discrimination did not separate them: AUC 0.797 versus 0.820 for T1WI ( P = 0.67), with no detectable pairwise difference. Late fusion had the highest net benefit at every threshold from 0.35 to 0.60. A consensus O-RADS reading reached an AUC of 0.920. Decision-level fusion gave a model with no better discrimination than the best single sequence but lower Brier scores and far fewer false positives. Its value is a calibrated probability that can be recomputed locally rather than a higher AUC, and it did not exceed O-RADS; with nine external events these comparisons are hypothesis-generating.
Authors
- Zhilin Zhao (ORCID: https://orcid.org/0000-0001-6391-8423)
- Du Hai (ORCID: https://orcid.org/0009-0002-6543-3854)
- Fengqiao Zhao
- Jingyuan QI
- Xiaoyu Guo
- Xiaojuan Xu
- Jiajia Li
- Meilan Zhang
Institutions
- Wuhan University (CN)
- Heilongjiang Provincial Hospital (CN)
- Fifth Hospital In Wuhan (CN)
Publication Details
- Journal
- Scientific Reports
- Published
- 2026-11-25
- DOI
- https://doi.org/10.1038/s41598-026-81009-8
- Primary Topic
- Radiomics and Machine Learning in Medical Imaging
- Type
- article
- Field-Weighted Citation Impact
- 0.00