Generational development of a self-contained dual-axis solar power system—A design evolution

This paper describes a multi-year engineering development of a self-contained solar power system that uses dual-axis tracking to ensure improved efficiency. This system is designed to operate in remote and rugged environments with minimal human intervention. The iterative design process yielded three generations of systems that were increasingly productive and responsive to design issues identified during development. The generations are labeled T1V1, T1V2, and T1V3, and this nomenclature is used throughout the manuscript. Across the three generations, the systems scaled dramatically at each generation (from 1.58 to 9.28 kW to 18.56 kW of photovoltaic capacity, and from 9.6 to 16.13 to 32.2 kWh of battery storage), while preserving a 48 V direct current (VDC) bus and maintaining the underlying dual-axis tracking approach. A comparison test was used to establish performance metrics and yielded approximately 30% greater incident solar energy and 39% greater delivered electrical energy than the equivalent fixed-tilt array. Field tests at a test facility exposed mechanical and electrical design issues that had to be addressed. Among the most significant issues were tracker binding and emergency stop contacts. The second generation (T1V2) was evaluated over 245 days of operation, including during the winter in a mid-latitude location. The third generation added a containerized shipping configuration and other changes to improve performance. This paper discusses the three-generation design evolution and focuses on improvements that had the most significant impact on performance and reliability.

Authors

Institutions

Publication Details

Journal
Clean Energy Science and Technology
Published
2026-11-25
DOI
https://doi.org/10.18686/cest938
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Generational development of a self-contained dual-axis solar power system—A design evolution

John Abraham, David Pogue, Brian D. Plourde, Randy Sullwold et al.
Clean Energy Science and Technology
Photovoltaic System Optimization Techniques
article

Generational development of a self-contained dual-axis solar power system—A design evolution

John Abraham, David Pogue, Brian D. Plourde, Randy Sullwold, Jess Lyons, Lawrence DeLuney
article en

Abstract

This paper describes a multi-year engineering development of a self-contained solar power system that uses dual-axis tracking to ensure improved efficiency. This system is designed to operate in remote and rugged environments with minimal human intervention. The iterative design process yielded three generations of systems that were increasingly productive and responsive to design issues identified during development. The generations are labeled T1V1, T1V2, and T1V3, and this nomenclature is used throughout the manuscript. Across the three generations, the systems scaled dramatically at each generation (from 1.58 to 9.28 kW to 18.56 kW of photovoltaic capacity, and from 9.6 to 16.13 to 32.2 kWh of battery storage), while preserving a 48 V direct current (VDC) bus and maintaining the underlying dual-axis tracking approach. A comparison test was used to establish performance metrics and yielded approximately 30% greater incident solar energy and 39% greater delivered electrical energy than the equivalent fixed-tilt array. Field tests at a test facility exposed mechanical and electrical design issues that had to be addressed. Among the most significant issues were tracker binding and emergency stop contacts. The second generation (T1V2) was evaluated over 245 days of operation, including during the winter in a mid-latitude location. The third generation added a containerized shipping configuration and other changes to improve performance. This paper discusses the three-generation design evolution and focuses on improvements that had the most significant impact on performance and reliability.

Clean Energy Science and Technology
United States Army Corps of Engineers (US), University of St. Thomas - Minnesota (US), United States Army (US)
Photovoltaic System Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon