Advances in Parabolic Trough Solar Collector Technology: Optical Modeling, Performance Analysis, Solar Tracking, and an Illustrative Decarbonization Estimate

Industrial thermal energy is difficult to decarbonize. Parabolic trough collectors (PTCs) provide heating up to approximately 400 °C; however, optical performance affects the heating provided. In this study, an optical design procedure for a PTC with an area of 50 m2 is developed, with the geometry selected within recommended parameter ranges, giving a concentration ratio of approximately 94% of the theoretical maximum. The design uses Monte Carlo ray tracing within the software Tonatiuh to simulate a PTC with a silvered polymer reflector and selective absorber. A convergence test is performed for the number of rays used. Repeated simulations with different random seeds give a standard deviation of 0.03 percentage points in the optical efficiency at 106 rays. The transverse incidence angle is then scanned with circumsolar ratios of 10%, 20% and 40%, and the longitudinal incidence angle with a circumsolar ratio of 10%. Receiver flux patterns are analyzed, and PTC optical performance is simulated for a full day in Évora, Portugal. The simulation uses North–South single-axis tracking and is compared to that of an ideal two-axis system. Incident angle modifiers are found using cubic polynomial fitting. The longitudinal incidence angle is also compared to SEGS LS-2. The absolute optical efficiency is checked against an independent ray-tracing code. A total of 106 rays are used to give an accurate simulation. Optical efficiency decreases as the PTC becomes misaligned. Flux patterns show areas of shadowing and distortion of the focal point. Optical efficiency varies between 65.3% and 78.2% throughout the day (overall efficiency, including the cosine loss). Single-axis tracking reduces optical efficiency, relative to an ideal two-axis system, by approximately 8% at noon and up to 13% later in the day. The optical analysis for a single location and day gives guidance on how to orient and track the collector. For this single day, the absorbed energy is about 368 kWh; with assumed thermal and boiler efficiencies this corresponds to about 57 kg CO2 of avoided emissions for one collector, an illustrative order-of-magnitude figure that is neither an annual nor a validated result.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-25
DOI
https://doi.org/10.3390/en19235721
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Advances in Parabolic Trough Solar Collector Technology: Optical Modeling, Performance Analysis, Solar Tracking, and an Illustrative Decarbonization Estimate

João Carlos Martins, Md. Tofael Ahmed, Oumaima Mesbahi, Frederico J. Lapa Grilo et al.
Energies
Solar Thermal and Photovoltaic Systems
article

Advances in Parabolic Trough Solar Collector Technology: Optical Modeling, Performance Analysis, Solar Tracking, and an Illustrative Decarbonization Estimate

João Carlos Martins, Md. Tofael Ahmed, Oumaima Mesbahi, Frederico J. Lapa Grilo, Mouhaydine Tlemçani, Md Ekramul Haque
article en

Abstract

Industrial thermal energy is difficult to decarbonize. Parabolic trough collectors (PTCs) provide heating up to approximately 400 °C; however, optical performance affects the heating provided. In this study, an optical design procedure for a PTC with an area of 50 m2 is developed, with the geometry selected within recommended parameter ranges, giving a concentration ratio of approximately 94% of the theoretical maximum. The design uses Monte Carlo ray tracing within the software Tonatiuh to simulate a PTC with a silvered polymer reflector and selective absorber. A convergence test is performed for the number of rays used. Repeated simulations with different random seeds give a standard deviation of 0.03 percentage points in the optical efficiency at 106 rays. The transverse incidence angle is then scanned with circumsolar ratios of 10%, 20% and 40%, and the longitudinal incidence angle with a circumsolar ratio of 10%. Receiver flux patterns are analyzed, and PTC optical performance is simulated for a full day in Évora, Portugal. The simulation uses North–South single-axis tracking and is compared to that of an ideal two-axis system. Incident angle modifiers are found using cubic polynomial fitting. The longitudinal incidence angle is also compared to SEGS LS-2. The absolute optical efficiency is checked against an independent ray-tracing code. A total of 106 rays are used to give an accurate simulation. Optical efficiency decreases as the PTC becomes misaligned. Flux patterns show areas of shadowing and distortion of the focal point. Optical efficiency varies between 65.3% and 78.2% throughout the day (overall efficiency, including the cosine loss). Single-axis tracking reduces optical efficiency, relative to an ideal two-axis system, by approximately 8% at noon and up to 13% later in the day. The optical analysis for a single location and day gives guidance on how to orient and track the collector. For this single day, the absorbed energy is about 368 kWh; with assumed thermal and boiler efficiencies this corresponds to about 57 kg CO2 of avoided emissions for one collector, an illustrative order-of-magnitude figure that is neither an annual nor a validated result.

EnergiesVol. 19(23)
University of Évora (PT), Universidade Politécnica de Beja (PT), Center for Sci-Tech Research in EArth sysTem and Energy (PT)
Solar Thermal and Photovoltaic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon