Effects of non-uniform spacing on flow instability and structural dynamics of wall-mounted flexible plate arrays

The interaction between arrays of wall-mounted flexible plates and viscous flows is ubiquitous in both natural and engineering systems. While extensive studies have focused on uniform arrays, fluid-structure interactions in non-uniform arrays remain poorly understood. In this study, direct numerical simulations are performed to investigate the effects of non-uniform spacing on fluid- structure interactions in a two-dimensional array of wall-mounted flexible plates. The array consists of upstream and downstream portions with distinct spacings, and the coverage ratio (CR) of the upstream portion ranges from 10% to 50%. The results indicate that, compared with the corresponding uniform configuration, non-uniform spacing shifts the onset position of Kelvin-Helmholtz (K-H) vortices upstream when CR ≤ 30%. The portion at which the K-H vortex is triggered plays a key role in determining the oscillation frequency of the plates. Based on these findings, the oscillation characteristics of the plates and the drag distribution along the array are analyzed in terms of the combined effects of upstream-shifted onset position, oscillation frequency approaching the natural frequency, the increased number of elements in the downstream portion, and low-frequency flow components. From the perspective of enhancing array resistance, a configuration with larger upstream spacing and smaller downstream spacing is recommended for CR = 30% or 50%. To further exploit the intrinsic property that the dominant oscillation frequency of the plates consistently exceeds the natural frequency, a preliminary study incorporating heterogeneity in both bending rigidity and gap distance is conducted. The results show that replacing the downstream plates in high-resistance arrays that consider only non-uniform spacing with slightly stiffer ones further enhances the overall array resistance. These findings not only advance the understanding of fluid-structure interactions in heterogeneous arrays, but also provide practical guidance for applications requiring high resistance, such as riverbank and coast protection using flexible vegetation.

Authors

Publication Details

Journal
Figshare
Published
2026-11-25
DOI
https://doi.org/10.6084/m9.figshare.35117528
Primary Topic
Fluid Dynamics and Vibration Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Effects of non-uniform spacing on flow instability and structural dynamics of wall-mounted flexible plate arrays

Weilin Chen, Chunning Ji, Dong Xu, Zhimeng Zhang et al.
Figshare
Fluid Dynamics and Vibration Analysis
article

Effects of non-uniform spacing on flow instability and structural dynamics of wall-mounted flexible plate arrays

Weilin Chen, Chunning Ji, Dong Xu, Zhimeng Zhang, Jinyuan Ni
article en

Abstract

The interaction between arrays of wall-mounted flexible plates and viscous flows is ubiquitous in both natural and engineering systems. While extensive studies have focused on uniform arrays, fluid-structure interactions in non-uniform arrays remain poorly understood. In this study, direct numerical simulations are performed to investigate the effects of non-uniform spacing on fluid- structure interactions in a two-dimensional array of wall-mounted flexible plates. The array consists of upstream and downstream portions with distinct spacings, and the coverage ratio (CR) of the upstream portion ranges from 10% to 50%. The results indicate that, compared with the corresponding uniform configuration, non-uniform spacing shifts the onset position of Kelvin-Helmholtz (K-H) vortices upstream when CR ≤ 30%. The portion at which the K-H vortex is triggered plays a key role in determining the oscillation frequency of the plates. Based on these findings, the oscillation characteristics of the plates and the drag distribution along the array are analyzed in terms of the combined effects of upstream-shifted onset position, oscillation frequency approaching the natural frequency, the increased number of elements in the downstream portion, and low-frequency flow components. From the perspective of enhancing array resistance, a configuration with larger upstream spacing and smaller downstream spacing is recommended for CR = 30% or 50%. To further exploit the intrinsic property that the dominant oscillation frequency of the plates consistently exceeds the natural frequency, a preliminary study incorporating heterogeneity in both bending rigidity and gap distance is conducted. The results show that replacing the downstream plates in high-resistance arrays that consider only non-uniform spacing with slightly stiffer ones further enhances the overall array resistance. These findings not only advance the understanding of fluid-structure interactions in heterogeneous arrays, but also provide practical guidance for applications requiring high resistance, such as riverbank and coast protection using flexible vegetation.

Figshare
Fluid Dynamics and Vibration Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon