Application of Patient-Based p Control Chart for Quality Control in a Clinical Laboratory

Background: Patient-based QC is a critical complementary tool for laboratory quality management. We evaluated the application and statistical performance of a patient-based p (a proportion-based statistical control chart) across quantitative and qualitative laboratory assays. Methods: We collected 413,586 valid test records involving 10 laboratory assays and divided them into training and verification datasets. P control charts were constructed using daily positive proportions and sample-size-specific limits. Monte Carlo simulations evaluated in-control performance, shift-detection performance, and sensitivity to group size using theoretical binomial shifts, empirical bootstrap simulations with analytical bias, and fixed subgroup sizes. Results: Empirical false-positive rates under in-control conditions ranged from 0.25% to 0.50%. Detection power increased with the magnitude of event-proportion or analytical shifts, whereas directional asymmetry occurred for thresholds located in distribution tails. Sample-size simulations showed greater stabilization of false-positive rates at daily subgroup sizes of ≥ 200. With clinical monitoring, the p control chart identified sustained increases in HbA1c positivity exceeding the diagnostic cut-off and detected persistent changes in total protein patient-result proportions that were not accompanied by conventional internal QC violations. Clinical decision limits-based charts for Na and K generated fewer signals than did reference intervals-based charts. In HBsAg monitoring, the p control chart remained within control limits following reagent lot replacement, whereas the corresponding Levey–Jennings charts showed an approximately 4-SD shift. Conclusions: The patient-based p control chart complemented laboratory QC analysis, with performance influenced by positive rate, threshold location, and subgroup size.

Authors

Institutions

Publication Details

Journal
Annals of Laboratory Medicine
Published
2026-11-25
DOI
https://doi.org/10.3343/alm.2026.0493
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Application of Patient-Based p Control Chart for Quality Control in a Clinical Laboratory

Jiali Liu, Yuzhu Huang, Zhiguo Wang, Pingan Zhang et al.
Annals of Laboratory Medicine
Clinical Laboratory Practices and Quality Control
article

Application of Patient-Based p Control Chart for Quality Control in a Clinical Laboratory

Jiali Liu, Yuzhu Huang, Zhiguo Wang, Pingan Zhang, Wanzhou Xu, Tingting Long
article en

Abstract

Background: Patient-based QC is a critical complementary tool for laboratory quality management. We evaluated the application and statistical performance of a patient-based p (a proportion-based statistical control chart) across quantitative and qualitative laboratory assays. Methods: We collected 413,586 valid test records involving 10 laboratory assays and divided them into training and verification datasets. P control charts were constructed using daily positive proportions and sample-size-specific limits. Monte Carlo simulations evaluated in-control performance, shift-detection performance, and sensitivity to group size using theoretical binomial shifts, empirical bootstrap simulations with analytical bias, and fixed subgroup sizes. Results: Empirical false-positive rates under in-control conditions ranged from 0.25% to 0.50%. Detection power increased with the magnitude of event-proportion or analytical shifts, whereas directional asymmetry occurred for thresholds located in distribution tails. Sample-size simulations showed greater stabilization of false-positive rates at daily subgroup sizes of ≥ 200. With clinical monitoring, the p control chart identified sustained increases in HbA1c positivity exceeding the diagnostic cut-off and detected persistent changes in total protein patient-result proportions that were not accompanied by conventional internal QC violations. Clinical decision limits-based charts for Na and K generated fewer signals than did reference intervals-based charts. In HBsAg monitoring, the p control chart remained within control limits following reagent lot replacement, whereas the corresponding Levey–Jennings charts showed an approximately 4-SD shift. Conclusions: The patient-based p control chart complemented laboratory QC analysis, with performance influenced by positive rate, threshold location, and subgroup size.

Annals of Laboratory Medicine
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Wuhan University (CN), Renmin Hospital of Wuhan University (CN), National Center for Clinical Laboratories (CN)
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon