Evaluation of BioFire® FilmArray® and GENECUBE® for Rapid Molecular Diagnosis of Periprosthetic Hip Joint Infection Using Implant Sonication Fluid

Periprosthetic joint infection (PJI) is difficult to diagnose because implants can develop biofilms. Fully automated polymerase chain reaction (PCR) systems rapidly identify organisms in PJI, while implant sonication may improve detection of biofilm-forming organisms. This study evaluated the diagnostic performance of automated PCR using sonication fluid from implants removed from patients with suspected hip PJI. Thirty patients undergoing revision total hip arthroplasty for PJI or aseptic loosening were enrolled. PJI was diagnosed according to the 2018 International Consensus Meeting criteria. Synovial fluid culture was performed, and both synovial fluid and implant sonication fluid were tested using the GENECUBE® and BioFire® FilmArray® Joint Infection Panel (JI Panel). Sensitivity and specificity were calculated for each test. Fifteen patients (50.0%) were diagnosed with PJI. Synovial fluid could not be obtained because of a dry tap in one PJI case (3.3%) and two aseptic loosening cases (6.7%). In synovial fluid, sensitivity was 57.1% for bacterial culture and GENECUBE® and 64.3% for the JI Panel; it increased to 85.7% when both fully automated PCR systems were combined. In implant sonication fluid, sensitivity was 46.7% for GENECUBE® and 66.7% for the BioFire® Joint Infection Panel, increasing to 93.3% when both fully automated PCR systems were combined. No false-positive results occurred in any sample, and specificity was 100% for every test method. CLINICAL SIGNIFICANCE STATEMENT: Combining the two fully automated PCR systems improves the diagnostic performance for PJI. Implant sonication fluid may provide an alternative specimen for molecular testing, particularly when synovial fluid cannot be obtained.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Research®
Published
2026-11-25
DOI
https://doi.org/10.1002/jor.70323
Primary Topic
Orthopedic Infections and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Evaluation of BioFire® FilmArray® and GENECUBE® for Rapid Molecular Diagnosis of Periprosthetic Hip Joint Infection Using Implant Sonication Fluid

Hiroyuki Ike, Hironori Yamane, Koki Abe, Ken Kumagai et al.
Journal of Orthopaedic Research®
Orthopedic Infections and Treatments
article

Evaluation of BioFire® FilmArray® and GENECUBE® for Rapid Molecular Diagnosis of Periprosthetic Hip Joint Infection Using Implant Sonication Fluid

Hiroyuki Ike, Hironori Yamane, Koki Abe, Ken Kumagai, Yuta Hieda, Yutaka Inaba, Naomi Kobayashi, Masashi Shimoda, Hyonmin Choe, Hiroto Kono
article en

Abstract

Periprosthetic joint infection (PJI) is difficult to diagnose because implants can develop biofilms. Fully automated polymerase chain reaction (PCR) systems rapidly identify organisms in PJI, while implant sonication may improve detection of biofilm-forming organisms. This study evaluated the diagnostic performance of automated PCR using sonication fluid from implants removed from patients with suspected hip PJI. Thirty patients undergoing revision total hip arthroplasty for PJI or aseptic loosening were enrolled. PJI was diagnosed according to the 2018 International Consensus Meeting criteria. Synovial fluid culture was performed, and both synovial fluid and implant sonication fluid were tested using the GENECUBE® and BioFire® FilmArray® Joint Infection Panel (JI Panel). Sensitivity and specificity were calculated for each test. Fifteen patients (50.0%) were diagnosed with PJI. Synovial fluid could not be obtained because of a dry tap in one PJI case (3.3%) and two aseptic loosening cases (6.7%). In synovial fluid, sensitivity was 57.1% for bacterial culture and GENECUBE® and 64.3% for the JI Panel; it increased to 85.7% when both fully automated PCR systems were combined. In implant sonication fluid, sensitivity was 46.7% for GENECUBE® and 66.7% for the BioFire® Joint Infection Panel, increasing to 93.3% when both fully automated PCR systems were combined. No false-positive results occurred in any sample, and specificity was 100% for every test method. CLINICAL SIGNIFICANCE STATEMENT: Combining the two fully automated PCR systems improves the diagnostic performance for PJI. Implant sonication fluid may provide an alternative specimen for molecular testing, particularly when synovial fluid cannot be obtained.

Journal of Orthopaedic Research®Vol. 44(12)
Yokohama City University Medical Center (JP), Yokohama City University (JP)
Orthopedic Infections and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon