Reproducibility and variability of visual capillary refill time assessment by intensive care physicians: comparison with near-infrared spectroscopy and automated video analysis in a cross-sectional observational study

Background Capillary refill time (CRT) is a widely used bedside marker of peripheral perfusion in intensive care, and its clinical relevance has grown after recent randomized trials incorporated it into hemodynamic resuscitation algorithms. Reproducibility under routine conditions remains poorly characterized, and objective tools to reduce observer-dependent variability are lacking. We developed a custom Python-based software for automated colorimetric CRT analysis and compared visual assessment with this tool and near-infrared spectroscopy (NIRS) in a controlled experimental model. Methods Eight healthy adult volunteers underwent three conditions: baseline, venous congestion at 50% of diastolic blood pressure (DBP), and congestion at 75% DBP. Tissue oxygen saturation (StO₂) was recorded continuously by NIRS every 3 s. Fingertip-pulp compression videos were obtained at 20, 40, 60, 80, and 240 s. Sixteen ICU clinicians assessed 2401 coded videos in random order. The Python colorimetric tool was applied to valid recordings. Reproducibility was evaluated with variance-component models, intraclass correlation coefficients (ICC), coefficients of repeatability (CR), and linear mixed-effects models. Results Mean visual CRT was 1.77 ± 0.65 s. No significant effects of congestion condition (F = 1.45, p = 0.23) or time (F = 1.48, p = 0.230) were detected; marginal R² was 0.04 and conditional R² was 0.44. Interobserver ICC was 0.52 (95% bootstrap CI 0.42–0.61), with a CR of 1.20 s; mean intraobserver ICC was 0.69 (range 0.42–0.84). Simulations showed ICC rising to 0.76 with three observers, 0.84 with five, and 0.92 with ten. NIRS (904 observations) detected significant condition- and time-related changes (p < 0.001); late-phase StO₂ differed by 8.46% between congestion levels, and nadir StO₂ was lower under greater congestion (p = 0.0018). Automated analysis of 53 recordings yielded a mean CRT of 3.89 ± 1.26 s, a significant congestion effect (F = 6.32, p = 0.016; marginal R² 0.12, conditional R² 0.48), and a mean between-condition difference of 0.68 s (p = 0.017). Conclusions Visual CRT showed moderate reproducibility and did not detect graded perfusion changes. Both NIRS and the Python-based automated software identified condition-related differences that visual assessment missed. These results call for cautious interpretation of isolated CRT when small serial changes inform clinical decisions, and support further evaluation of automated approaches in critically ill patients.

Authors

Institutions

Publication Details

Journal
Intensive Care Medicine Experimental
Published
2026-11-25
DOI
https://doi.org/10.1186/s40635-026-01001-4
Primary Topic
Sepsis Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Reproducibility and variability of visual capillary refill time assessment by intensive care physicians: comparison with near-infrared spectroscopy and automated video analysis in a cross-sectional observational study

Mario Omar Pozo, Facundo Javier Gutierrez, Juan Ignacio Mazza, Nicole Alejandra Goette et al.
Intensive Care Medicine Experimental
Sepsis Diagnosis and Treatment
article

Reproducibility and variability of visual capillary refill time assessment by intensive care physicians: comparison with near-infrared spectroscopy and automated video analysis in a cross-sectional observational study

Mario Omar Pozo, Facundo Javier Gutierrez, Juan Ignacio Mazza, Nicole Alejandra Goette, Gastón Eduardo Murias
article en

Abstract

Background Capillary refill time (CRT) is a widely used bedside marker of peripheral perfusion in intensive care, and its clinical relevance has grown after recent randomized trials incorporated it into hemodynamic resuscitation algorithms. Reproducibility under routine conditions remains poorly characterized, and objective tools to reduce observer-dependent variability are lacking. We developed a custom Python-based software for automated colorimetric CRT analysis and compared visual assessment with this tool and near-infrared spectroscopy (NIRS) in a controlled experimental model. Methods Eight healthy adult volunteers underwent three conditions: baseline, venous congestion at 50% of diastolic blood pressure (DBP), and congestion at 75% DBP. Tissue oxygen saturation (StO₂) was recorded continuously by NIRS every 3 s. Fingertip-pulp compression videos were obtained at 20, 40, 60, 80, and 240 s. Sixteen ICU clinicians assessed 2401 coded videos in random order. The Python colorimetric tool was applied to valid recordings. Reproducibility was evaluated with variance-component models, intraclass correlation coefficients (ICC), coefficients of repeatability (CR), and linear mixed-effects models. Results Mean visual CRT was 1.77 ± 0.65 s. No significant effects of congestion condition (F = 1.45, p = 0.23) or time (F = 1.48, p = 0.230) were detected; marginal R² was 0.04 and conditional R² was 0.44. Interobserver ICC was 0.52 (95% bootstrap CI 0.42–0.61), with a CR of 1.20 s; mean intraobserver ICC was 0.69 (range 0.42–0.84). Simulations showed ICC rising to 0.76 with three observers, 0.84 with five, and 0.92 with ten. NIRS (904 observations) detected significant condition- and time-related changes (p < 0.001); late-phase StO₂ differed by 8.46% between congestion levels, and nadir StO₂ was lower under greater congestion (p = 0.0018). Automated analysis of 53 recordings yielded a mean CRT of 3.89 ± 1.26 s, a significant congestion effect (F = 6.32, p = 0.016; marginal R² 0.12, conditional R² 0.48), and a mean between-condition difference of 0.68 s (p = 0.017). Conclusions Visual CRT showed moderate reproducibility and did not detect graded perfusion changes. Both NIRS and the Python-based automated software identified condition-related differences that visual assessment missed. These results call for cautious interpretation of isolated CRT when small serial changes inform clinical decisions, and support further evaluation of automated approaches in critically ill patients.

Intensive Care Medicine ExperimentalVol. 14(1)
Hospital Británico de Buenos Aires (AR)
Sepsis Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon