BRISANCE: A GPU-Accelerated Pipeline for Somatic Short-Variant Detection in Whole-Genome Sequencing Data

Post-sequencing computational processing of tumor-normal whole-genome sequencing (WGS) remains computationally intensive and can delay somatic variant detection in clinical and translational workflows. We developed and evaluated BRISANCE, a graphics processing unit (GPU)-accelerated pipeline based on NVIDIA Parabricks for detecting somatic single-nucleotide variants and short insertions/deletions, using matched tumor-normal WGS data from the Cancer Genome in a Bottle HG008 pancreatic ductal adenocarcinoma model. Concordance with the DRAGEN-derived comparator call set was assessed using allele-level variant-set comparison, RTG Tools haplotype-aware benchmarking, and IGV manual review of four literature-reported HG008-T sample loci. Runtime was measured in two analyses: a fixed CPU-GPU comparison and GPU-scaling experiments. At the analyzed whole-genome call-set level, the PASS-filtered, positive-TLOD Parabricks set and the PASS-filtered DRAGEN set contained 17,134 and 16,885 variants, respectively, sharing 14,430 variants and yielding an intersection-over-union overlap of 73.66%. Shared fractions were 76.09% for single-nucleotide variants and 69.06% for insertions/deletions. Using the DRAGEN-derived call set as a comparator rather than a validated truth set, RTG score-based filtering increased comparator-based precision from 0.8375 to 0.9110 and F-measure from 0.8569 to 0.8821. Qualitative IGV review showed consistent read-level support at the four selected HG008-T loci. In the fixed CPU-GPU comparison using the HG008 tumor-normal dataset, the summed runtime of the evaluated preprocessing and somatic variant-calling components was 10.6 hours for the GPU-accelerated workflow versus 219.4 hours for the CPU-based workflow, corresponding to a 95.1% reduction and a 20.6-fold speedup under the evaluated conditions. In GPU-scaling experiments, alignment/preprocessing reached its shortest runtimes with 6-8 GPUs, whereas MutectCaller reached its shortest runtime with 2-3 GPUs, depending on CPU-thread configuration. Full-input Nextflow execution reproduced the historical CHROM/POS/REF/ALT record set, and a configuration-based interface was developed for user-defined analyses.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-11-25
DOI
https://doi.org/10.64898/2026.11.24.768872
Primary Topic
Cancer Genomics and Diagnostics
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

BRISANCE: A GPU-Accelerated Pipeline for Somatic Short-Variant Detection in Whole-Genome Sequencing Data

Saloê Bispo Poubel, Silvia Aparecida Teixeira, Rui Manuel Reis, Murilo Porfírio de Aguiar et al.
bioRxiv (Cold Spring Harbor Laboratory)
Cancer Genomics and Diagnostics
preprint

BRISANCE: A GPU-Accelerated Pipeline for Somatic Short-Variant Detection in Whole-Genome Sequencing Data

Saloê Bispo Poubel, Silvia Aparecida Teixeira, Rui Manuel Reis, Murilo Porfírio de Aguiar, Luciane Sussuchi da Silva, Leticia Conceição dos Santos
preprint en

Abstract

Post-sequencing computational processing of tumor-normal whole-genome sequencing (WGS) remains computationally intensive and can delay somatic variant detection in clinical and translational workflows. We developed and evaluated BRISANCE, a graphics processing unit (GPU)-accelerated pipeline based on NVIDIA Parabricks for detecting somatic single-nucleotide variants and short insertions/deletions, using matched tumor-normal WGS data from the Cancer Genome in a Bottle HG008 pancreatic ductal adenocarcinoma model. Concordance with the DRAGEN-derived comparator call set was assessed using allele-level variant-set comparison, RTG Tools haplotype-aware benchmarking, and IGV manual review of four literature-reported HG008-T sample loci. Runtime was measured in two analyses: a fixed CPU-GPU comparison and GPU-scaling experiments. At the analyzed whole-genome call-set level, the PASS-filtered, positive-TLOD Parabricks set and the PASS-filtered DRAGEN set contained 17,134 and 16,885 variants, respectively, sharing 14,430 variants and yielding an intersection-over-union overlap of 73.66%. Shared fractions were 76.09% for single-nucleotide variants and 69.06% for insertions/deletions. Using the DRAGEN-derived call set as a comparator rather than a validated truth set, RTG score-based filtering increased comparator-based precision from 0.8375 to 0.9110 and F-measure from 0.8569 to 0.8821. Qualitative IGV review showed consistent read-level support at the four selected HG008-T loci. In the fixed CPU-GPU comparison using the HG008 tumor-normal dataset, the summed runtime of the evaluated preprocessing and somatic variant-calling components was 10.6 hours for the GPU-accelerated workflow versus 219.4 hours for the CPU-based workflow, corresponding to a 95.1% reduction and a 20.6-fold speedup under the evaluated conditions. In GPU-scaling experiments, alignment/preprocessing reached its shortest runtimes with 6-8 GPUs, whereas MutectCaller reached its shortest runtime with 2-3 GPUs, depending on CPU-thread configuration. Full-input Nextflow execution reproduced the historical CHROM/POS/REF/ALT record set, and a configuration-based interface was developed for user-defined analyses.

bioRxiv (Cold Spring Harbor Laboratory)
Hospital de Câncer de Barretos (BR)
Cancer Genomics and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon