An Empirical Comparison of Lesion Sampling for Microaneurysm Segmentation within and Across Datasets

Background and Aims: Microaneurysms (MAs) occupy a small fraction of fundus images, making their segmentation sensitive to how training patches are selected. This study compares three patch-sampling strategies and examines whether their within-dataset detection benefits persist across datasets. Methods: Three U-Net models were trained on FGADR using random retinal-region sampling (P0), lesion-guided sampling (P1), or image-conditioned size-stratified sampling (P2). The architecture, loss function and training budget remained unchanged. Performance was assessed on 274 FGADR validation images and 149 DDR validation images using image-wise Dice, pixel average precision (AP), lesion recall and false positives (FP) per image. No DDR images were used for training or threshold tuning. Results: At threshold 0.5 on FGADR validation, P1 increased pooled small-lesion recall from 0.5556 to 0.6173, with false positives per MA-empty image increasing from 7.77 to 9.01. P2 gave the highest macro-averaged pixel average precision (AP; 0.1955), although its FROC-style curve was close to P1 over their shared range. This ordering did not persist across the reported metrics on DDR validation. P0 had the highest Dice, AP, and image-wise recall; P1 had slightly higher small-lesion recall than P0. The lowest false-positive rates, obtained with P2, coincided with the lowest recall. Conclusion: In this single-run comparison, sampling benefits depended on the metric and evaluation dataset. The findings describe development-set results from one architecture, seed, and transfer direction; they do not establish a general ranking of sampling strategies or clinical effectiveness.

Authors

Institutions

Publication Details

Journal
Asian Journal of Research in Computer Science
Published
2026-11-24
DOI
https://doi.org/10.9734/ajrcos/2026/v19i11939
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

An Empirical Comparison of Lesion Sampling for Microaneurysm Segmentation within and Across Datasets

Juhong Liao, Bing Guan, Yuyue Peng, Min Chen et al.
4 links
Asian Journal of Research in Computer Science
Retinal Imaging and Analysis
article

An Empirical Comparison of Lesion Sampling for Microaneurysm Segmentation within and Across Datasets

Juhong Liao, Bing Guan, Yuyue Peng, Min Chen, Xiaoluan Chen
article en

Abstract

Background and Aims: Microaneurysms (MAs) occupy a small fraction of fundus images, making their segmentation sensitive to how training patches are selected. This study compares three patch-sampling strategies and examines whether their within-dataset detection benefits persist across datasets. Methods: Three U-Net models were trained on FGADR using random retinal-region sampling (P0), lesion-guided sampling (P1), or image-conditioned size-stratified sampling (P2). The architecture, loss function and training budget remained unchanged. Performance was assessed on 274 FGADR validation images and 149 DDR validation images using image-wise Dice, pixel average precision (AP), lesion recall and false positives (FP) per image. No DDR images were used for training or threshold tuning. Results: At threshold 0.5 on FGADR validation, P1 increased pooled small-lesion recall from 0.5556 to 0.6173, with false positives per MA-empty image increasing from 7.77 to 9.01. P2 gave the highest macro-averaged pixel average precision (AP; 0.1955), although its FROC-style curve was close to P1 over their shared range. This ordering did not persist across the reported metrics on DDR validation. P0 had the highest Dice, AP, and image-wise recall; P1 had slightly higher small-lesion recall than P0. The lowest false-positive rates, obtained with P2, coincided with the lowest recall. Conclusion: In this single-run comparison, sampling benefits depended on the metric and evaluation dataset. The findings describe development-set results from one architecture, seed, and transfer direction; they do not establish a general ranking of sampling strategies or clinical effectiveness.

Asian Journal of Research in Computer ScienceVol. 19(11)
Huizhou University (CN)
Good health and well-being
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon