Automated EEG seizure detection in neonates with hypoxic–ischemic encephalopathy using temporal and morphological modeling

Background Seizures are common in neonates with hypoxic–ischemic encephalopathy (HIE) and may be difficult to recognize clinically. Automated electroencephalography (EEG) analysis is therefore important for neonatal neurological monitoring. However, variable EEG backgrounds, brief abnormal discharges, and marked inter-patient differences remain major challenges. Methods We developed a temporal EEG framework for neonatal seizure detection. Multi-scale temporal convolution was used to capture local waveform changes, while a hierarchical state-space encoder modeled longer temporal dependencies. Micro-temporal morphological evolution gating, temporal-state attention pooling, and nuisance-state suppression were further introduced to enhance seizure-related information. The model was evaluated on the Helsinki dataset of 79 neonates and an independent clinical HIE cohort of 34 neonates. EEG signals were converted to an 18-channel longitudinal bipolar montage and segmented into 10 s windows with a 5 s stride. Patient-level stratified five-fold cross-validation was performed under the SPEED evaluation framework. Results On the Helsinki dataset, the model achieved an AUC of 94.78 % ± 2.75 %, AP of 82.58 % ± 11.46 %, F1 score of 75.69 % ± 11.81 %, and MCC of 73.48 % ± 11.37 %. Sensitivity and Specificity were 70.42 % ± 13.59 % and 98.16 % ± 1.15 %, respectively. On the clinical cohort, the corresponding values were 95.51 % ± 2.36 %, 84.24 % ± 10.31 %, 77.31 % ± 10.48 %, and 75.29 % ± 10.08 %, with Sensitivity of 71.28 % ± 12.14 % and Specificity of 98.54 % ± 0.63 %. Ablation and patient-level analyses supported the complementary contributions of morphology modeling, temporal-state selection, and interference suppression. Conclusion The proposed framework achieved consistent seizure detection performance in both public and clinical neonatal HIE EEG datasets. It may provide useful technical support for automated seizure screening and bedside neurological monitoring in neonates with HIE.

Authors

Institutions

Publication Details

Journal
Frontiers in Pediatrics
Published
2026-11-24
DOI
https://doi.org/10.3389/fped.2026.2008200
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Automated EEG seizure detection in neonates with hypoxic–ischemic encephalopathy using temporal and morphological modeling

Tianfang Dong, Shina Zhan, 沈颖婕, Wan Tao et al.
2 links
Frontiers in Pediatrics
EEG and Brain-Computer Interfaces
article

Automated EEG seizure detection in neonates with hypoxic–ischemic encephalopathy using temporal and morphological modeling

Tianfang Dong, Shina Zhan, 沈颖婕, Wan Tao, Feitian Li, Jinqian Yu
article en

Abstract

Background Seizures are common in neonates with hypoxic–ischemic encephalopathy (HIE) and may be difficult to recognize clinically. Automated electroencephalography (EEG) analysis is therefore important for neonatal neurological monitoring. However, variable EEG backgrounds, brief abnormal discharges, and marked inter-patient differences remain major challenges. Methods We developed a temporal EEG framework for neonatal seizure detection. Multi-scale temporal convolution was used to capture local waveform changes, while a hierarchical state-space encoder modeled longer temporal dependencies. Micro-temporal morphological evolution gating, temporal-state attention pooling, and nuisance-state suppression were further introduced to enhance seizure-related information. The model was evaluated on the Helsinki dataset of 79 neonates and an independent clinical HIE cohort of 34 neonates. EEG signals were converted to an 18-channel longitudinal bipolar montage and segmented into 10 s windows with a 5 s stride. Patient-level stratified five-fold cross-validation was performed under the SPEED evaluation framework. Results On the Helsinki dataset, the model achieved an AUC of 94.78 % ± 2.75 %, AP of 82.58 % ± 11.46 %, F1 score of 75.69 % ± 11.81 %, and MCC of 73.48 % ± 11.37 %. Sensitivity and Specificity were 70.42 % ± 13.59 % and 98.16 % ± 1.15 %, respectively. On the clinical cohort, the corresponding values were 95.51 % ± 2.36 %, 84.24 % ± 10.31 %, 77.31 % ± 10.48 %, and 75.29 % ± 10.08 %, with Sensitivity of 71.28 % ± 12.14 % and Specificity of 98.54 % ± 0.63 %. Ablation and patient-level analyses supported the complementary contributions of morphology modeling, temporal-state selection, and interference suppression. Conclusion The proposed framework achieved consistent seizure detection performance in both public and clinical neonatal HIE EEG datasets. It may provide useful technical support for automated seizure screening and bedside neurological monitoring in neonates with HIE.

Frontiers in PediatricsVol. 14
Beijing Children’s Hospital (CN)
Good health and well-being
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon