Development of a sensitive and rapid on-site detection method for avian influenza virus in wildlife using reverse transcription loop-mediated isothermal amplification

The global spread of H5 high pathogenicity avian influenza virus (HPAIV) severely threatens wildlife, posing a critical challenge for conservation medicine. Although immunochromatographic (IC) kits are commonly used for on-site diagnosis of wildlife samples, their low sensitivity often results in false negatives. Highly sensitive molecular methods, such as reverse transcription quantitative polymerase chain reaction (RT-qPCR), are often impractical for field use because of the need for sophisticated equipment. Therefore, a sensitive and affordable on-site diagnostic tool is essential for early detection of HPAIV in wildlife samples collected in the field. In this study, a reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay targeting M gene for the on-site detection of avian influenza virus (AIV) was developed and evaluated. Initially, the assay using liquid reagents was validated in terms of specificity and sensitivity to confirm the appropriateness of the reaction mixture composition. This assay exhibited high specificity and exclusively detected AIVs without cross-reactivity. Sensitivity analysis using swabs from HPAIV-infected ducks demonstrated that the assay was comparable to RT-qPCR but substantially superior to IC kits. The reaction reagents were lyophilized to minimize the testing procedure for practical field use. This simplified protocol using lyophilized reagents and a portable incubator yielded results that were highly concordant with those of RT-qPCR. These findings indicate that the RT-LAMP assay serves as a robust diagnostic resource, supporting wildlife conservation strategies by enabling rapid, sensitive, and early detection of AIV infection in the field.

Authors

Institutions

Publication Details

Journal
Journal of Veterinary Medical Science
Published
2026-11-25
DOI
https://doi.org/10.1292/jvms.26-0403
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Development of a sensitive and rapid on-site detection method for avian influenza virus in wildlife using reverse transcription loop-mediated isothermal amplification

Fuminori Maki, Yoshihiro Sakoda, Masaki Izawa, Norikazu Isoda et al.
Journal of Veterinary Medical Science
Biosensors and Analytical Detection
article

Development of a sensitive and rapid on-site detection method for avian influenza virus in wildlife using reverse transcription loop-mediated isothermal amplification

Fuminori Maki, Yoshihiro Sakoda, Masaki Izawa, Norikazu Isoda, Takahiro Hiono, Tomoki Kawase, Mitsuaki Okami, Tatsuru Morita, Yo Shimazu
article en

Abstract

The global spread of H5 high pathogenicity avian influenza virus (HPAIV) severely threatens wildlife, posing a critical challenge for conservation medicine. Although immunochromatographic (IC) kits are commonly used for on-site diagnosis of wildlife samples, their low sensitivity often results in false negatives. Highly sensitive molecular methods, such as reverse transcription quantitative polymerase chain reaction (RT-qPCR), are often impractical for field use because of the need for sophisticated equipment. Therefore, a sensitive and affordable on-site diagnostic tool is essential for early detection of HPAIV in wildlife samples collected in the field. In this study, a reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay targeting M gene for the on-site detection of avian influenza virus (AIV) was developed and evaluated. Initially, the assay using liquid reagents was validated in terms of specificity and sensitivity to confirm the appropriateness of the reaction mixture composition. This assay exhibited high specificity and exclusively detected AIVs without cross-reactivity. Sensitivity analysis using swabs from HPAIV-infected ducks demonstrated that the assay was comparable to RT-qPCR but substantially superior to IC kits. The reaction reagents were lyophilized to minimize the testing procedure for practical field use. This simplified protocol using lyophilized reagents and a portable incubator yielded results that were highly concordant with those of RT-qPCR. These findings indicate that the RT-LAMP assay serves as a robust diagnostic resource, supporting wildlife conservation strategies by enabling rapid, sensitive, and early detection of AIV infection in the field.

Journal of Veterinary Medical Science
Hokkaido University (JP), Nippon GENE Co., Ltd. (Japan) (JP), One Health Research Center, Hokkaido University (JP), Institute for Vaccine Research and Development, Hokkaido University (JP), Hokkaido University International Institute for Zoonosis Control (JP)
Japan Agency for Medical Research and Development, Environmental Restoration and Conservation Agency, Hokkaido University
Good health and well-being
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon