Seismic performance evaluation of long-span CFST arch ring structure considering steel uniform corrosion effects

Owing to the limited research on the seismic performance of concrete-filled steel tubular (CFST) arch bridges subjected to long-term corrosion deterioration, and considering that the arch ring structure is the primary load-bearing structure providing seismic resistance of such bridges, this study aimed to evaluate the impact of steel corrosion on the seismic performance of CFST arch ring structure. A typical long-span deck-type CFST arch bridge in southwest China was selected as the prototype, and a finite element model of its arch ring was developed in OpenSees and validated against a Midas counterpart through comparison of the dynamic characteristics. Firstly, a dual-parameter failure criterion based on deformation and energy accumulation was introduced. Damage evaluation models for the arch ring components and the overall arch ring were adopted from previous studies to conduct seismic damage assessment at both component and structural levels. Based on the uniform corrosion model, non-corroded, 50-year corroded, and 100-year corroded CFST arch ring models were established. Incremental dynamic analysis (IDA) was then carried out under 8 selected ground motions, and IDA curves of damage index for each component and the arch ring at different corrosion levels were obtained. Finally, fragility analysis was conducted to evaluate the effects of steel corrosion on the exceedance probabilities of different damage states of the arch ring. The results indicated that the arch springing region was the main damage concentration region of the arch ring, and transverse connection bars were more susceptible to severe damage under higher seismic intensity levels. The seismic damage intensified at both the component and structural levels with increasing peak ground acceleration (PGA). Seismic performance of arch ring components deteriorated significantly with increasing service life due to steel corrosion, leading to an increased probability of the arch ring reaching higher damage states under the same seismic intensity. Therefore, for long-span CFST arch bridges with a service life exceeding 50 years, periodic on-site inspections and seismic performance evaluation are recommended.

Authors

Publication Details

Journal
International Journal of Structural Stability and Dynamics
Published
2026-11-24
DOI
https://doi.org/10.1142/s0219455428501064
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Seismic performance evaluation of long-span CFST arch ring structure considering steel uniform corrosion effects

Pupeng Ai, Shuangshuang Jin, Yujie Tan, Fangting Wang
3 links
International Journal of Structural Stability and Dynamics
Seismic Performance and Analysis
article

Seismic performance evaluation of long-span CFST arch ring structure considering steel uniform corrosion effects

Pupeng Ai, Shuangshuang Jin, Yujie Tan, Fangting Wang
article en

Abstract

Owing to the limited research on the seismic performance of concrete-filled steel tubular (CFST) arch bridges subjected to long-term corrosion deterioration, and considering that the arch ring structure is the primary load-bearing structure providing seismic resistance of such bridges, this study aimed to evaluate the impact of steel corrosion on the seismic performance of CFST arch ring structure. A typical long-span deck-type CFST arch bridge in southwest China was selected as the prototype, and a finite element model of its arch ring was developed in OpenSees and validated against a Midas counterpart through comparison of the dynamic characteristics. Firstly, a dual-parameter failure criterion based on deformation and energy accumulation was introduced. Damage evaluation models for the arch ring components and the overall arch ring were adopted from previous studies to conduct seismic damage assessment at both component and structural levels. Based on the uniform corrosion model, non-corroded, 50-year corroded, and 100-year corroded CFST arch ring models were established. Incremental dynamic analysis (IDA) was then carried out under 8 selected ground motions, and IDA curves of damage index for each component and the arch ring at different corrosion levels were obtained. Finally, fragility analysis was conducted to evaluate the effects of steel corrosion on the exceedance probabilities of different damage states of the arch ring. The results indicated that the arch springing region was the main damage concentration region of the arch ring, and transverse connection bars were more susceptible to severe damage under higher seismic intensity levels. The seismic damage intensified at both the component and structural levels with increasing peak ground acceleration (PGA). Seismic performance of arch ring components deteriorated significantly with increasing service life due to steel corrosion, leading to an increased probability of the arch ring reaching higher damage states under the same seismic intensity. Therefore, for long-span CFST arch bridges with a service life exceeding 50 years, periodic on-site inspections and seismic performance evaluation are recommended.

International Journal of Structural Stability and Dynamics
Industry, innovation and infrastructure
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon