Confirmation of Sengstaken-Blakemore Tube Placement Using POCUS During Life-Threatening Upper Gastrointestinal Bleed: A Case Report

Introduction: Acute gastroesophageal variceal hemorrhage is a life-threatening emergency requiring rapid hemostasis. Sengstaken-Blakemore tube placement remains an important temporizing intervention in patients with refractory bleeding; however, improper positioning, particularly inflation of the gastric balloon within the esophagus, can result in catastrophic complications including esophageal rupture. Radiographic confirmation is traditionally recommended but may delay intervention in unstable patients. Point-of-care ultrasound (POCUS) has emerged as a potential alternative for real-time confirmation of balloon placement. Our case demonstrates how POCUS can be used to rapidly and safely confirm intragastric Sengstaken-Blakemore tube placement prior to balloon inflation in an unstable patient with massive variceal hemorrhage and hemorrhagic shock. Case Report: We describe a 62-year-old woman with severe alcohol use disorder who presented with massive hematemesis and hemorrhagic shock. Despite administration of ceftriaxone, octreotide, pantoprazole, vasopressors, and activation of massive transfusion protocol, the patient remained hemodynamically unstable with ongoing large-volume hematemesis. After endotracheal intubation, a Sengstaken-Blakemore tube was placed. Point-of-care ultrasound using a curvilinear probe was performed prior to full balloon inflation, demonstrating the gastric balloon within the stomach through dynamic visualization of balloon movement and intragastric air. Following confirmation, the gastric balloon was fully inflated and traction applied, resulting in effective tamponade and improved hemodynamics. Subsequent endoscopy confirmed bleeding esophageal and gastroesophageal varices, which were successfully banded, and the patient was ultimately discharged from the hospital. Conclusion: Point-of-care ultrasound is a tool that can be rapidly employed at the bedside to confirm intragastric placement of Sengstaken-Blakemore tubes, potentially improving time to tamponade and minimizing the risk of catastrophic malposition-related complications in patients with massive variceal hemorrhage.

Authors

Publication Details

Journal
Clinical Practice and Cases in Emergency Medicine
Published
2026-11-24
DOI
https://doi.org/10.5811/cpcem.65067
Primary Topic
Gastrointestinal Bleeding Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Confirmation of Sengstaken-Blakemore Tube Placement Using POCUS During Life-Threatening Upper Gastrointestinal Bleed: A Case Report

Eric Boccio, Michael T. Dalley, David Kinas, Preet Sawhney et al.
3 links
Clinical Practice and Cases in Emergency Medicine
Gastrointestinal Bleeding Diagnosis and Treatment
article

Confirmation of Sengstaken-Blakemore Tube Placement Using POCUS During Life-Threatening Upper Gastrointestinal Bleed: A Case Report

Eric Boccio, Michael T. Dalley, David Kinas, Preet Sawhney, Heleina Dopazo, Yonghoon Lee
article en

Abstract

Introduction: Acute gastroesophageal variceal hemorrhage is a life-threatening emergency requiring rapid hemostasis. Sengstaken-Blakemore tube placement remains an important temporizing intervention in patients with refractory bleeding; however, improper positioning, particularly inflation of the gastric balloon within the esophagus, can result in catastrophic complications including esophageal rupture. Radiographic confirmation is traditionally recommended but may delay intervention in unstable patients. Point-of-care ultrasound (POCUS) has emerged as a potential alternative for real-time confirmation of balloon placement. Our case demonstrates how POCUS can be used to rapidly and safely confirm intragastric Sengstaken-Blakemore tube placement prior to balloon inflation in an unstable patient with massive variceal hemorrhage and hemorrhagic shock. Case Report: We describe a 62-year-old woman with severe alcohol use disorder who presented with massive hematemesis and hemorrhagic shock. Despite administration of ceftriaxone, octreotide, pantoprazole, vasopressors, and activation of massive transfusion protocol, the patient remained hemodynamically unstable with ongoing large-volume hematemesis. After endotracheal intubation, a Sengstaken-Blakemore tube was placed. Point-of-care ultrasound using a curvilinear probe was performed prior to full balloon inflation, demonstrating the gastric balloon within the stomach through dynamic visualization of balloon movement and intragastric air. Following confirmation, the gastric balloon was fully inflated and traction applied, resulting in effective tamponade and improved hemodynamics. Subsequent endoscopy confirmed bleeding esophageal and gastroesophageal varices, which were successfully banded, and the patient was ultimately discharged from the hospital. Conclusion: Point-of-care ultrasound is a tool that can be rapidly employed at the bedside to confirm intragastric placement of Sengstaken-Blakemore tubes, potentially improving time to tamponade and minimizing the risk of catastrophic malposition-related complications in patients with massive variceal hemorrhage.

Clinical Practice and Cases in Emergency MedicineVol. 0(0)
Good health and well-being
Gastrointestinal Bleeding Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon