Measurement of the electron temperature in the channel of a Hall thruster using a xenon collisional-radiative model

In this work, radial and axial measurement of optical emission spectra from Hall thruster are analysed using a xenon collisional radiative model. The collisional radiative model includes transitions between the ground state, the 1s and the 2p states of the xenon atom due to electron impact excitation and de-excitation and radiative decay with an escape factor correction. The extraction of the plasma parameters relies on an optimisation loop that fits the 15 emission lines of the xenon atoms in the near-infrared range to the experimental ones and yields the effective electron temperature. The loop mainly constrains the effective electron temperature but it includes also the density of electrons and neutrals as fitting parameters. The predictions of the latter are considered only qualitatively. The model predictions of the effective electron temperature are benchmarked against Langmuir probe measurements in the plume region. The measurements are line-of-sight integrated and are performed at equally-spaced positions in the plume along the axial direction and in the channel along the radial direction. Measurements of the axial profile in the plume show a strong electron cooling and an exponential decrease of the electron density, linked to the plume expansion and the neutral background in the vacuum chamber. The measurements of the radial profile within the channel reveal, as expected, a hot core and a sharp decrease near the channel walls. A parametric study with the applied anode voltage and the mass flow rate demonstrate the capabilities and limitations of the method for non-invasive monitoring of the electron temperature in the thruster plume and the thruster channel.

Authors

Institutions

Publication Details

Journal
Plasma Sources Science and Technology
Published
2026-11-24
DOI
https://doi.org/10.1088/1361-6595/aec668
Primary Topic
Low-Pressure Plasma Processing and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Measurement of the electron temperature in the channel of a Hall thruster using a xenon collisional-radiative model

Anne Bourdon, Pascal Chabert, Alexandre Leduc, Tsanko V. Tsankov et al.
Plasma Sources Science and Technology
Low-Pressure Plasma Processing and Diagnostics
article

Measurement of the electron temperature in the channel of a Hall thruster using a xenon collisional-radiative model

Anne Bourdon, Pascal Chabert, Alexandre Leduc, Tsanko V. Tsankov, Tarek Ben Slimane, L. Schiesko
article en

Abstract

In this work, radial and axial measurement of optical emission spectra from Hall thruster are analysed using a xenon collisional radiative model. The collisional radiative model includes transitions between the ground state, the 1s and the 2p states of the xenon atom due to electron impact excitation and de-excitation and radiative decay with an escape factor correction. The extraction of the plasma parameters relies on an optimisation loop that fits the 15 emission lines of the xenon atoms in the near-infrared range to the experimental ones and yields the effective electron temperature. The loop mainly constrains the effective electron temperature but it includes also the density of electrons and neutrals as fitting parameters. The predictions of the latter are considered only qualitatively. The model predictions of the effective electron temperature are benchmarked against Langmuir probe measurements in the plume region. The measurements are line-of-sight integrated and are performed at equally-spaced positions in the plume along the axial direction and in the channel along the radial direction. Measurements of the axial profile in the plume show a strong electron cooling and an exponential decrease of the electron density, linked to the plume expansion and the neutral background in the vacuum chamber. The measurements of the radial profile within the channel reveal, as expected, a hot core and a sharp decrease near the channel walls. A parametric study with the applied anode voltage and the mass flow rate demonstrate the capabilities and limitations of the method for non-invasive monitoring of the electron temperature in the thruster plume and the thruster channel.

Plasma Sources Science and Technology
Centre National de la Recherche Scientifique (FR), École Polytechnique (FR)
European Commission, Agence Nationale de la Recherche, Centre National d’Etudes Spatiales, Centre National de la Recherche Scientifique, Sorbonne Université, HORIZON EUROPE Digital, Industry and Space
Low-Pressure Plasma Processing and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon