Development and internal validation of a prediction model for repair integrity after arthroscopic rotator cuff repair using a Swiss multicenter cohort

Background Repair integrity is one of the most studied outcomes following arthroscopic rotator cuff repair (ARCR). Clinical prediction models supporting management of expectation towards repair integrity after ARCR, developed using large nationwide data, remain lacking. Our objective was to develop and internally validate clinical prediction models for repair integrity for patients undergoing an ARCR. Methods Individual participants data from 973 patients underwent an ARCR across 19 study centers performed by 53 surgeons between June 2020 and November 2021 as part of a prospective cohort study (ARCR_Pred). Post-operative magnetic resonance imaging (MRI) examinations were performed on 309 patients across nine study centers. A series of multivariable logistic regression models were developed for a primary outcome (describing 12-month full-thickness rotator cuff defect, identified using reported adverse events (AE) and MRI findings). We assessed four model specifications based on expert knowledge (Expert 10/5), literature (Systematic Review), or dynamic selection (LASSO) across three timepoints (baseline, operation, 6-week). Apparent and bootstrap-validated (B = 200) Brier score, AUC, calibration (slope/intercept), and clinical usefulness were compared. Immediately after performing surgery, treating surgeons also estimated the probability (0-100%) of recurrent rotator cuff defects in their patient. Sensitivity analyses on secondary outcomes and the supraspinatus subpopulation were conducted. Results Prevalence of 12-month full-thickness rotator cuff defect was 24% (N = 80/329). LASSO models showed the best performance metrics after bootstrap validation, consistently increasing from baseline: (AUC = 0.72, 95% CI: 0.67 to 0.79), to operation (AUC = 0.74, 95% CI: 0.69 to 0.80), to 6-week (AUC = 0.76, 95% CI: 0.72 to 0.82). Clinicians had a limited discriminative ability (AUC = 0.58, 95% CI: 0.50 to 0.65) and predictions were miscalibrated (calibration slope: 1.95). Tear size, body mass index and smoking status were identified across timepoints. Intra-operative tear retraction grade, total number of anchors used during the surgery or external rotation at 6-week also contributed to model performance: https://arcrpred.shinyapps.io/ARCR_Pred-Repair-Integrity/. Conclusions The developed models may support counseling of clinicians and patients about the risk of recurrent rotator cuff defect preoperatively, perioperatively or at the planned six-week examination. As the outcome was assessed in a predefined MRI sub-cohort, external validation is required before the models are used to guide preventive measures, such as individualized rehabilitation protocols, in high-risk patients. Trial registration ClinicalTrials.gov, NCT04321005, registered on March 3, 2020.

Authors

Institutions

Publication Details

Journal
BMC Musculoskeletal Disorders
Published
2026-11-24
DOI
https://doi.org/10.1186/s12891-026-10757-5
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Development and internal validation of a prediction model for repair integrity after arthroscopic rotator cuff repair using a Swiss multicenter cohort

Christian Candrian, Sebastian Müller, Claudio Rosso, Karl Wieser et al.
2 links
BMC Musculoskeletal Disorders
Shoulder Injury and Treatment
article

Development and internal validation of a prediction model for repair integrity after arthroscopic rotator cuff repair using a Swiss multicenter cohort

Christian Candrian, Sebastian Müller, Claudio Rosso, Karl Wieser, Thomas Stojanov, Laurent Audigé, Matthias P. Flury, Vilijam Zdravkovic, Philipp Moroder, Bernhard Jost, Andreas Marc Müller, Alexandre Lädermann, ARCR_Pred Study Group
article en

Abstract

Background Repair integrity is one of the most studied outcomes following arthroscopic rotator cuff repair (ARCR). Clinical prediction models supporting management of expectation towards repair integrity after ARCR, developed using large nationwide data, remain lacking. Our objective was to develop and internally validate clinical prediction models for repair integrity for patients undergoing an ARCR. Methods Individual participants data from 973 patients underwent an ARCR across 19 study centers performed by 53 surgeons between June 2020 and November 2021 as part of a prospective cohort study (ARCR_Pred). Post-operative magnetic resonance imaging (MRI) examinations were performed on 309 patients across nine study centers. A series of multivariable logistic regression models were developed for a primary outcome (describing 12-month full-thickness rotator cuff defect, identified using reported adverse events (AE) and MRI findings). We assessed four model specifications based on expert knowledge (Expert 10/5), literature (Systematic Review), or dynamic selection (LASSO) across three timepoints (baseline, operation, 6-week). Apparent and bootstrap-validated (B = 200) Brier score, AUC, calibration (slope/intercept), and clinical usefulness were compared. Immediately after performing surgery, treating surgeons also estimated the probability (0-100%) of recurrent rotator cuff defects in their patient. Sensitivity analyses on secondary outcomes and the supraspinatus subpopulation were conducted. Results Prevalence of 12-month full-thickness rotator cuff defect was 24% (N = 80/329). LASSO models showed the best performance metrics after bootstrap validation, consistently increasing from baseline: (AUC = 0.72, 95% CI: 0.67 to 0.79), to operation (AUC = 0.74, 95% CI: 0.69 to 0.80), to 6-week (AUC = 0.76, 95% CI: 0.72 to 0.82). Clinicians had a limited discriminative ability (AUC = 0.58, 95% CI: 0.50 to 0.65) and predictions were miscalibrated (calibration slope: 1.95). Tear size, body mass index and smoking status were identified across timepoints. Intra-operative tear retraction grade, total number of anchors used during the surgery or external rotation at 6-week also contributed to model performance: https://arcrpred.shinyapps.io/ARCR_Pred-Repair-Integrity/. Conclusions The developed models may support counseling of clinicians and patients about the risk of recurrent rotator cuff defect preoperatively, perioperatively or at the planned six-week examination. As the outcome was assessed in a predefined MRI sub-cohort, external validation is required before the models are used to guide preventive measures, such as individualized rehabilitation protocols, in high-risk patients. Trial registration ClinicalTrials.gov, NCT04321005, registered on March 3, 2020.

BMC Musculoskeletal Disorders
University of Basel (CH), University of Zurich (CH), University of St.Gallen (CH), Kantonsspital St. Gallen (CH), University Hospital of Basel (CH), Ente Ospedaliero Cantonale (CH), Schulthess-Klinik (CH), Universitätsklinik Balgrist (CH), Kantonsspital Baselland Standort Bruderholz (CH), Hôpital de la Tour (CH), Università della Svizzera italiana (CH)
Universität Basel, Inselspital, Universitätsspital Bern, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Good health and well-being
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon