Continuous glucose monitoring during warm-water ocean apnea diving: practical considerations for field deployment

Introduction Apnea diving in warm tropical waters involves repeated exertion, pronounced autonomic responses, and intermittent hypoxia, creating challenges for continuous physiological monitoring in the field. Continuous glucose monitoring (CGM) can capture interstitial glucose dynamics under free-living conditions, but field deployment guidance for open-water apnea diving is sparse. Prolonged multi-hour apnea sessions may deplete carbohydrate stores and precipitate end-of-session hypoglycemia, which could compound hypoxic stress, motivating continuous field monitoring. Here, we report an implementation-focused protocol for CGM deployment during warm-water ocean apnea diving and outline practical considerations to support field use. Methods We describe an implementation-focused protocol for deploying CGM during routine warm-water, open-ocean apnea diving. Eighteen adult apnea divers (n=18) completed repeated apnea sessions with surface recovery. The objective was to evaluate operational feasibility across multi-dive sessions rather than interpret individual-dive glucose responses. The protocol focused on standardizing sensor placement, adhesion reinforcement, anchor-timestamp synchronization, structured logging, and prespecified feasibility criteria, with capillary finger-prick glucose obtained at rest for comparison. Results CGM devices were deployed across 560 dives spanning a wide range of real-world diving exposures. Eleven of 18 participant-sessions (61.1%) achieved first-attempt sensor retention and data export; the remaining seven (38.9%) required sensor replacement; all seven occurred before the diving day (six from adhesive detachment during showering or heavy sweating, one from failed sensor insertion), rather than from wetsuit transitions or in-water exposure. All 18 sessions ultimately yielded exportable, time-aligned data, though in-dive glucose measurements were not analyzed. Paired capillary measurements at rest showed strong linear correspondence with contemporaneous CGM readings. As the comparison used a small, non-independent sample obtained at rest during surface intervals, it is presented as an exploratory surface-rest functional check rather than formal validation of agreement. Conclusions CGM can be deployed during warm-water ocean apnea diving when sensor adhesion, scanning logistics, and time alignment are planned a priori. These findings demonstrate sensor retention and data availability under field conditions, not analytical accuracy during apnea, immersion, or pressure exposure, which this study did not evaluate. Standardized deployment and reporting practices may improve reproducibility and support multi-sensor physiological monitoring in apnea research, though not for real-time in-water decision-making.

Authors

Institutions

Publication Details

Journal
Frontiers in Physiology
Published
2026-11-24
DOI
https://doi.org/10.3389/fphys.2026.1869201
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Continuous glucose monitoring during warm-water ocean apnea diving: practical considerations for field deployment

Ezra M. Cervera, Michael Orr
2 links
Frontiers in Physiology
Diabetes Management and Research
article

Continuous glucose monitoring during warm-water ocean apnea diving: practical considerations for field deployment

Ezra M. Cervera, Michael Orr
article en

Abstract

Introduction Apnea diving in warm tropical waters involves repeated exertion, pronounced autonomic responses, and intermittent hypoxia, creating challenges for continuous physiological monitoring in the field. Continuous glucose monitoring (CGM) can capture interstitial glucose dynamics under free-living conditions, but field deployment guidance for open-water apnea diving is sparse. Prolonged multi-hour apnea sessions may deplete carbohydrate stores and precipitate end-of-session hypoglycemia, which could compound hypoxic stress, motivating continuous field monitoring. Here, we report an implementation-focused protocol for CGM deployment during warm-water ocean apnea diving and outline practical considerations to support field use. Methods We describe an implementation-focused protocol for deploying CGM during routine warm-water, open-ocean apnea diving. Eighteen adult apnea divers (n=18) completed repeated apnea sessions with surface recovery. The objective was to evaluate operational feasibility across multi-dive sessions rather than interpret individual-dive glucose responses. The protocol focused on standardizing sensor placement, adhesion reinforcement, anchor-timestamp synchronization, structured logging, and prespecified feasibility criteria, with capillary finger-prick glucose obtained at rest for comparison. Results CGM devices were deployed across 560 dives spanning a wide range of real-world diving exposures. Eleven of 18 participant-sessions (61.1%) achieved first-attempt sensor retention and data export; the remaining seven (38.9%) required sensor replacement; all seven occurred before the diving day (six from adhesive detachment during showering or heavy sweating, one from failed sensor insertion), rather than from wetsuit transitions or in-water exposure. All 18 sessions ultimately yielded exportable, time-aligned data, though in-dive glucose measurements were not analyzed. Paired capillary measurements at rest showed strong linear correspondence with contemporaneous CGM readings. As the comparison used a small, non-independent sample obtained at rest during surface intervals, it is presented as an exploratory surface-rest functional check rather than formal validation of agreement. Conclusions CGM can be deployed during warm-water ocean apnea diving when sensor adhesion, scanning logistics, and time alignment are planned a priori. These findings demonstrate sensor retention and data availability under field conditions, not analytical accuracy during apnea, immersion, or pressure exposure, which this study did not evaluate. Standardized deployment and reporting practices may improve reproducibility and support multi-sensor physiological monitoring in apnea research, though not for real-time in-water decision-making.

Frontiers in PhysiologyVol. 17
University of Guam (GU)
National Institutes of Health
Good health and well-being
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon